Schneider Electric A9F93270 Miniature Circuit Breaker

Rate this product

Schneider Electric A9F93270 Acti9 iC60L is a 2-pole, 0.5 A MCB with a B-curve thermal-magnetic trip unit and 15 kA breaking capacity at 400 V AC. With up to 100 kA Icu at 380–415 V AC, it provides precise protection for suitable low-current control, auxiliary, instrumentation, and distribution circuits.

Main documents

SpecificationValue
ManufacturerSchneider Electric
Product SeriesActi9 iC60L
Product CodeA9F93270
Product TypeMiniature Circuit Breaker (MCB)
Rated Current0.5 A
Number of Poles2P
Number of Protected Poles2
Tripping CurveB
Trip Unit TechnologyThermal-magnetic
Network TypeAC/DC
Rated Voltage400 V AC
Frequency50/60 Hz
Rated Insulation Voltage (Ui)500 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Breaking Capacity (Icn)15 kA at 400 V AC according to EN/IEC 60898-1
Ultimate Breaking Capacity (Icu)100 kA at 380–415 V AC according to EN/IEC 60947-2
Ultimate Breaking Capacity (Icu)100 kA at 220–240 V AC according to EN/IEC 60947-2
Ultimate Breaking Capacity (Icu)100 kA at 100–133 V AC according to EN/IEC 60947-2
Ultimate Breaking Capacity (Icu)70 kA at 440 V AC according to EN/IEC 60947-2
DC Breaking Capacity (Icu)20 kA at ≤125 V DC according to EN/IEC 60947-2
Utilisation CategoryCategory A
Isolation FunctionYes
Mounting TypeDIN Rail
Degree of ProtectionIP20
Energy Limitation ClassClass 3
Pollution Degree3
Overvoltage CategoryIV
Compatible AccessoriesAuxiliary devices, remote monitoring devices, Vigi residual-current protection devices
StandardsEN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2

.

Product Description

Electrical protection is not determined by current rating alone. The relationship between the protected load, conductor capacity, fault current, and tripping behaviour defines whether a miniature circuit breaker is appropriate for a particular installation. This becomes even more important in low-current circuits, where an incorrectly selected protection characteristic can affect normal operation or leave equipment insufficiently protected.

The Schneider Electric A9F93270 belongs to the Acti9 iC60L range and is configured as a 2-pole miniature circuit breaker rated at 0.5 A. It uses a B-curve thermal-magnetic trip unit, providing protection against both overload and short-circuit conditions. With two protected poles, the device is intended for applications where both conductors require coordinated protection within the same modular breaker.

The 0.5 A rating makes the A9F93270 particularly relevant to low-current electrical circuits rather than conventional high-load distribution applications. The selection of such a low-rated breaker is normally associated with equipment and circuits where the permissible current is limited and protection must be closely matched to the connected components.

The B-curve characteristic provides a different operating response from the Z-curve devices within the same product family. It is designed for circuits where the instantaneous magnetic tripping threshold associated with a B characteristic is suitable for the expected operating conditions. This makes correct curve selection an important part of the protection design rather than simply choosing a breaker based on amperage.

The short-circuit performance of the A9F93270 is also significant. At 400 V AC and 50/60 Hz, the breaker has a 15 kA rated breaking capacity according to EN/IEC 60898-1. Under EN/IEC 60947-2, the ultimate breaking capacity reaches 100 kA at 380–415 V AC, while the specified Icu values vary according to the operating voltage. The device can also be used in DC networks within its applicable ratings.

The breaker is designed for use in distribution applications and incorporates a number of functions associated with the Acti9 platform. Its design supports electrical isolation according to the relevant standards, while the broader system provides options for auxiliary devices, remote monitoring, and Vigi residual-current protection.

Schneider Electric A9F93270 Technical Specifications

The A9F93270 has a relatively specialised electrical profile: 0.5 A rated current, two protected poles, and a B-curve thermal-magnetic trip unit. These characteristics should be considered together because changing any one of them can alter the way the protection device interacts with the circuit.

Its interruption capability is considerably higher than its nominal current rating might suggest. The 15 kA Icn at 400 V AC rating and the high Icu values specified under IEC/EN 60947-2 provide the breaker with substantial short-circuit interruption capability for a device intended for low-current circuits.

Rated Current – 0.5 A

The 0.5 A rated current defines the nominal current level for which the A9F93270 is intended. This makes it suitable for circuits where the electrical load is relatively small and where protection needs to be closely aligned with the current-carrying capacity of the wiring and connected equipment.

A low-rated circuit breaker should not be selected simply because the connected equipment consumes little power. Cable characteristics, ambient conditions, operating current, and the behaviour of upstream and downstream protection must also be considered when determining the appropriate protection device.

B-Curve Tripping Characteristic

The A9F93270 uses a B-curve characteristic, which determines the magnetic tripping response of the breaker during high-current fault conditions. This characteristic is commonly associated with circuits where excessive inrush current is not expected and where relatively sensitive instantaneous protection is required.

The B curve therefore gives the A9F93270 a distinct operating profile compared with C-curve and Z-curve versions of the iC60L family. Selecting the correct curve helps prevent unwanted tripping during normal operation while maintaining the required response to fault currents.

Two-Pole Protection

The 2P configuration provides protection across two poles within one circuit breaker. Both poles are protected, allowing the device to be incorporated into suitable single-phase and other two-conductor circuit arrangements where coordinated disconnection is required.

Using a two-pole device also provides a compact method of protecting the circuit without relying on separate single-pole breakers.

Short-Circuit Breaking Capacity

The A9F93270 provides a 15 kA Icn at 400 V AC, 50/60 Hz according to EN/IEC 60898-1. Under EN/IEC 60947-2, the specified ultimate breaking capacity reaches 100 kA at 380–415 V AC, with additional ratings applying at other voltage levels. For DC applications, the specified Icu reaches 20 kA at voltages up to 125 V DC.

These values describe the breaker’s ability to interrupt fault currents under defined standardised conditions. The prospective short-circuit current at the actual installation point should be evaluated before selecting the device.

Thermal-Magnetic Trip Technology

The A9F93270 combines thermal and magnetic protection within one trip unit. The thermal mechanism responds to an overload that persists for a sufficient period, while the magnetic mechanism is intended to operate rapidly when a high fault current occurs.

This dual response allows the breaker to address different types of abnormal current conditions without requiring separate protection devices for overload and short-circuit protection.

AC and DC Network Compatibility

The A9F93270 is specified for both AC and DC networks. Its principal AC rating is 400 V at 50/60 Hz, while the applicable DC interruption capability is specified separately according to voltage.

This distinction is important because the breaking capacity of a circuit breaker cannot automatically be assumed to remain identical when the supply changes from AC to DC.

Features and Benefits of the Schneider Electric A9F93270

The A9F93270 offers a combination that is particularly suited to low-current protection: a 0.5 A nominal current, B-curve response, and two protected poles. Rather than being designed as a general-purpose high-load breaker, its electrical configuration allows it to be incorporated into circuits where current levels and protection requirements are relatively precise.

The high short-circuit interruption ratings provide another layer of protection capability. The device can interrupt significant fault currents despite its low nominal current rating, provided the operating conditions remain within the specified ratings.

The Acti9 iC60L architecture also allows the breaker to form part of a broader protection arrangement. Auxiliary devices, remote monitoring solutions, and Vigi residual-current protection can be incorporated where the installation requires additional functionality.

Key Benefits

The A9F93270 provides low-current circuit protection with a B-curve response and two protected poles. Its thermal-magnetic technology addresses both sustained overloads and short-circuit events, while its high interruption capability allows it to be considered for installations with significant prospective fault currents.

The compact modular construction and Acti9 accessory ecosystem further support its use in professional electrical assemblies where space, protection coordination, and additional monitoring functions need to be considered together.

Applications of the Schneider Electric A9F93270 Miniature Circuit Breaker

The electrical characteristics of the A9F93270 make it suitable for applications where the protected circuit operates at a low current and requires a B-curve response. The exact application depends on the load characteristics, conductor rating, supply arrangement, and prospective fault current.

Control and Auxiliary Circuits

Low-current auxiliary circuits can require their own dedicated protection to prevent a fault in one section of an electrical installation from affecting other circuits. The 0.5 A rating of the A9F93270 allows it to be used where the protected circuit operates within this current range.

Electronic Equipment

Electronic systems often contain components that can be damaged by abnormal current conditions. A correctly selected low-rated circuit breaker can provide an additional level of protection for suitable equipment and associated wiring.

Instrumentation Circuits

Instrumentation systems may contain relatively low-current wiring and components that require carefully matched circuit protection. The A9F93270 can be incorporated into suitable circuits where its B-curve response and 0.5 A rating correspond to the electrical design.

Industrial Control Panels

Control cabinets frequently contain multiple circuits with different current requirements. A dedicated 2P, 0.5 A breaker can provide independent protection for suitable low-current circuits while maintaining an organised modular panel layout.

Building Electrical Systems

Certain low-power circuits within commercial and building installations require dedicated overcurrent protection. The A9F93270 can be used where its current rating, B characteristic, and voltage ratings match the requirements of the installation.

Low-Current Distribution

The breaker can also be incorporated into selected low-current distribution arrangements where two-pole protection is required. Its high breaking capacity provides additional fault interruption capability when the prospective short-circuit current is within the specified limits.

Why Buy the Schneider Electric A9F93270?

The Schneider Electric A9F93270 combines a low 0.5 A rated current with a B-curve thermal-magnetic trip unit and two protected poles. This configuration makes it important to select the device according to the actual electrical behaviour of the circuit rather than relying solely on physical compatibility.

Its Acti9 iC60L platform also provides functions beyond basic overcurrent protection. The range supports electrical isolation and can be expanded with compatible accessories for auxiliary signalling, remote monitoring, and residual-current protection.

Advantages of Choosing the Right Model

A circuit breaker performs correctly only when its current rating and tripping characteristic are compatible with the circuit it protects. The A9F93270 provides a defined 0.5 A B-curve protection profile for applications where these characteristics are required.

Its two-pole construction, thermal-magnetic protection, high fault interruption capability, and modular design make it a practical choice for appropriately designed low-current electrical systems.

Buy the Schneider Electric A9F93270 from GeeTech

When purchasing a miniature circuit breaker, the complete manufacturer reference should be checked carefully. Differences in current rating, pole configuration, or tripping curve can result in significantly different electrical behaviour even when two devices appear almost identical.

GeeTech supplies Schneider Electric equipment for industrial electrical projects, control panels, replacement requirements, and professional procurement applications, including sourcing for the A9F93270 reference.

Why Purchase from GeeTech?

GeeTech supports international customers with product sourcing, quotation services, technical assistance, and worldwide shipping. Procurement can cover individual replacement requirements as well as larger quantities for industrial projects and electrical panel production.

Schneider Electric A9F93270 Price

The price of the Schneider Electric A9F93270 depends on factors such as availability, purchasing quantity, market conditions, logistics costs, and currency exchange rates.

A current quotation provides a more accurate basis for purchasing, particularly when the requirement involves a specific manufacturer reference and quantity.

Frequently Asked Questions About the Schneider Electric A9F93270

The Schneider Electric A9F93270 is an Acti9 iC60L 2-pole miniature circuit breaker rated at 0.5 A and equipped with a B-curve thermal-magnetic trip unit. It is designed for suitable low-voltage AC and DC applications.

What is the rated current of the A9F93270?

The rated current is 0.5 A. The breaker should be selected only when this rating is compatible with the load, conductor capacity, and protection requirements of the installation.

How many poles does the A9F93270 have?

The A9F93270 is a 2-pole circuit breaker, with two protected poles.

What tripping curve does the A9F93270 use?

The device uses a B-curve characteristic. This provides a relatively sensitive magnetic response for applications where the expected inrush current is compatible with the B-curve operating range.

What is the breaking capacity of the A9F93270?

At 400 V AC, the A9F93270 has a 15 kA Icn according to EN/IEC 60898-1. Its ultimate breaking capacity under EN/IEC 60947-2 reaches 100 kA at 380–415 V AC.

Does the A9F93270 support DC circuits?

Yes. The product specifications identify the A9F93270 for AC and DC networks. For DC applications, the applicable interruption rating must be checked against the operating voltage and circuit configuration.

What protection technology does the A9F93270 use?

The circuit breaker uses thermal-magnetic protection, combining thermal overload protection with magnetic short-circuit protection.

Is the A9F93270 suitable for low-current circuits?

Yes. Its 0.5 A rated current makes it particularly relevant to low-current applications where the circuit protection needs to be closely matched to the operating current.

Can the A9F93270 be used in industrial control panels?

It can be used in suitable industrial control and auxiliary circuits where the 0.5 A rating, 2P configuration, B curve, and applicable voltage and fault ratings correspond to the system requirements.

Does the A9F93270 support additional accessories?

The Acti9 iC60L range supports compatible auxiliary devices, remote monitoring equipment, and Vigi residual-current protection solutions.

Is the A9F93270 still commercially available?

Schneider Electric regional product pages indicate that the reference has reached end of commercialization in some markets, with no direct replacement currently listed. Availability should therefore be confirmed before placing an order.

Can GeeTech supply the A9F93270 internationally?

GeeTech provides international sourcing and worldwide shipping for industrial electrical equipment. Availability, pricing, and delivery conditions can be confirmed according to the required quantity and destination.

Conclusion: Why Choose the Schneider Electric A9F93270?

The Schneider Electric A9F93270 Miniature Circuit Breaker is a specialised 2-pole, 0.5 A protection device from the Acti9 iC60L family. Its B-curve thermal-magnetic protection, 15 kA Icn at 400 V AC, and up to 100 kA Icu at 380–415 V AC give it a combination of low-current protection and substantial short-circuit interruption capability.

Its compact 2P configuration and compatibility with the Acti9 accessory ecosystem make it suitable for correctly specified control, auxiliary, instrumentation, electronic, and low-current distribution circuits. Because the reference has been discontinued in some markets, confirming current availability is particularly important when sourcing the exact A9F93270 model.

Frequently Asked Questions