Range Vigilohm
Device short name IFL12
product or component type Insulation fault locator
Device application Marine application
Standard environment application
electrical circuit type Medium or low disturbed network
Electrical circuit type Power circuit
Earthing system IT
Complementary
Network rated voltage 0…1000 V – AC at 45…65 Hz
0…1000 V – DC
Number of channels 12
Local signalling Yellow indicator light: insulation fault
Green/red indicator light: product status
Green indicator light: satisfactory insulation
Yellow flashing indicator light: transient fault
Green indicator light: configured threshold LED
Green indicator light: configured filtering LED
Yellow steady 1 LED per channel: insulation fault
Yellow flashing 1 LED per channel: transient fault/toroid disconnected
Threshold setting Alarm: high, medium, low
alarm per channel Alarm threshold: common to all feeders
Response time <= 5 s
auxiliary supply voltage 100…440 V DC +/- 15 %
100…440 V AC 45…65 Hz +/- 15 %
Power consumption in VA 20 VA
power consumption in W 6 W
Test function Manual
Auto test at start and every 5h
output contact 1 C/O standard
breaking capacity 250 V – AC at 6 A
48 V – DC at 1 A
Communication port protocol
Mounting mode Flush-mounted
Clip-on
Mounting support Panel
DIN rail
Mounting position Horizontal
Vertical
Connections – terminals Power supply: removable screw terminal block0.2…2.5 mm²
Output relay: removable screw terminal block0.2…2.5 mm²
Toroids inputs: removable screw terminal block0.2…1.5 mm²
Material Thermoplastic
Overvoltage category III
net weight 0.5 kg
Cut-out dimensions 92 x 104 mm
Height 110 mm
Width 108 mm
Depth 59 mm
Environment
IP degree of protection Case: IP20
Front face: IP54
Environmental characteristic Exposure to damp heat not in service conforming to IEC 60068-2-30
Exposure to damp heat in service conforming to IEC 60068-2-56
Salt mist conforming to IEC 60068-2-52
Operating altitude <= 3000 m
Pollution degree 2
Relative humidity 5…92 %
Type of installation Indoor
Standards IEC 60364-4-41
IEC 61010-1
IEC 60364-5-51
IEC 61557-9
Product certifications DNV-GL
CE
EAC
UL
cULus
Ambient air temperature for operation -25…55 °C
ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.0 cm
Package 1 Width 13.5 cm
Package 1 Length 18.5 cm
Package 1 Weight 519.0 g
Unit Type of Package 2 S03
Number of Units in Package 2 8
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 4.563 kg
Unit Type of Package 3 P06
Number of Units in Package 3 64
Package 3 Height 75 cm
Package 3 Width 80 cm
Package 3 Length 60 cm
Package 3 Weight 44.504 kg
Product Description

Schneider Power Monitoring and Control

Frequently Asked Questions

✅Power monitoring systems typically comprise a power metering device to gauge overall facility power consumption and assess power quality. Coupled with a monitoring system, these tools track energy distribution within the facility post-metering.

A Power Monitoring Device plays a crucial role in measuring power consumption, facilitating energy-saving endeavors. While electricity itself remains invisible, it represents a convenient and ubiquitous form of energy that transforms into various manifestations such as heat, light, sound, and power, all of which are extensively utilized.

Enhance safety and boost process availability with Vigilohm's range of insulation monitoring devices (IMDs). Designed for IT (ungrounded) networks, these devices offer a straightforward, dependable solution for insulation monitoring, communication, and fault location. Discover how this streamlined offering can elevate both personnel and equipment safety while optimizing process availability.

Insulation Monitors by DOLD: Insulation Monitoring Made Simple

DOLD's insulation monitors provide seamless insulation monitoring solutions. In the event of an insulation fault, the measuring circuit triggers, allowing a proportional small current to flow. The device's electronics evaluate this current, issuing a notification if the insulation resistance drops below a predefined threshold (response value).

Explore the Importance of Isolation Monitoring in High-Voltage Vehicle Systems

Isolation monitoring stands as a pivotal safety feature in high-voltage vehicle systems. In modern vehicles, the high-voltage system remains completely isolated from the vehicle chassis. This design safeguards against electrical shock by preventing a single fault in the high-voltage system from posing a risk to individuals.

Reviews

There are no reviews yet.

Be the first to review “IMDIFL12”

Your email address will not be published. Required fields are marked *

Start typing to see products you are looking for.