Product Catalogue

Download Product Catalogue

100% Genuine Products

Supplier of industrial electrical products

1 year warranty

The products have a warranty

A9F92272

5/5 - (5 votes)

iC60L – miniature circuit breaker – 2P – 1.6A – Z curve

Main documents

Main
Range of ProductModicon M171/M172
Product or Component TypeProgrammable controllers
Product Specific ApplicationHVAC
variantProgrammable
Total inputs/outputs18
Discrete input number2
Discrete output number1 relay outputs SPDT with independent common
2 relay outputs SPST with same common
3 relay outputs SPST with independent common
Discrete output current3 A relay SPST
3 A relay SPDT
Analogue input number8 configurable by pair
Analogue output number2 voltage/current 4…20 mA or 0…10 V or PWM (2 kHz)
Complementary
Number of port1 CAN port – screw terminal block
1 USB type A – USB type A female
1 USB type mini B – USB device port Mini-B
2 RS485 – screw terminal block Modbus serial link or BACnet MS/TP)
1 Ethernet – RJ45 Modbus TCP and BACnet IP with webserver)
Input/output number2 analog output
6 digital output
8 analog input
2 digital input
Discrete input logicSink or source (positive/negative) up to 2 kHz
Discrete input voltage24 V AC/DC
Discrete input current5 mA AC/DC
Input impedance10 kOhm
Analogue input typeNTC NK103 Beta 3977 temperature probe – 40…137 °C 0.1 °C 10 kOhm at 25 °C)
NTC 103AT-2 Beta 3435 temperature probe – 50…110 °C 0.1 °C 10 kOhm at 25 °C)
voltage 0…10 V 1 digit > 10 kOhm
voltage 0…5 V 1 digit > 20 kOhm absolute or ratiometric)
impedance 0…1500 hOhm 1 hOhm 10 kOhm
impedance 0…300 daOhm 1 daOhm 1500 Ohm
PTC temperature probe – 55…150 °C 0.1 °C 1500 Ohm
Pt 1000 temperature probe – 200…850 °C 0.1 °C 1500 Ohm
current 0…20 mA/4…20 mA 1 digit < 150 Ohm
direct input 10 kOhm Dry contact)
Measurement accuracy0…20 mA 0…4 mA +/- 2 % of full scale +/- 1 digit
0…20 mA 4…20 mA +/- 1 % of full scale +/- 1 digit
4…20 mA +/- 1 % of full scale +/- 1 digit
0…10 V +/- 1 % of full scale +/- 1 digit
0…5 V +/- 1 % of full scale +/- 1 digit
DaOhm 0…300 daOhm +/- 2.5 daOhm
NTC NK103 Beta 3977 – 40…+110 °C +/- 1 °C
NTC NK103 Beta 3977 110…137 °C +/- 1.9 °C
NTC 103AT-2 Beta 3435 – 50…110 °C +/- 1 °C
PTC – 55…155 °C +/- 1.1 °C
Pt 1000 – 200…-100 °C +/- 10 °C
Pt 1000 – 100…-50 °C +/- 2.5 °C
Pt 1000 – 50…100 °C +/- 1.5 °C
Pt 1000 100…400 °C +/- 2.4 °C
Pt 1000 400…850 °C +/- 10 °C
HOhm 0…750 hOhm +/- 8.5 hOhm
HOhm 750 hOhm…1500 hOhm +/- 24 hOhm
Sensor power supply5 V DC 40 mA supplied by the controller
24 V DC 100 mA supplied by the controller
[Us] rated supply voltage24 V +/- 10 % AC
20…38 V DC
Power consumption in W11 W 24 V AC/DC
Realtime clockBuilt-in clock, clock drift <= 30 s/month at -4…140 °F (-20…60 °C)
Display typeWithout Display
Overvoltage categoryII
Local signallingFor programmable 1 LED (red)
for programmable 1 LED (yellow)
for programmable 1 LED (green)
for power 1 LED (green)
Mounting SupportPanel mounting with accessory
DIN rail
Width2.8 in (72 mm)
Height4.3 in (110 mm)
Depth2.4 in (60.5 mm)
Net Weight0.4 lb(US) (0.2 kg)
Environment
IP degree of protectionIP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage categoryIV
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude0…2000 m
Ambient air temperature for operation-35…70 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height3.5 cm
Package 1 Width7.1 cm
Package 1 Length9.3 cm
Package 1 Weight225.0 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height8.1 cm
Package 2 Width10.1 cm
Package 2 Length22.6 cm
Package 2 Weight1.406 kg
Unit Type of Package 3S03
Number of Units in Package 366
Package 3 Height30.0 cm
Package 3 Width30.0 cm
Package 3 Length40.0 cm
Package 3 Weight15.953 kg
Product Description

Schneider Miniature Circuit Breaker

Frequently Asked Questions

When comparing Schneider and Siemens circuit breakers, both brands offer unique strengths and advantages, making them top choices in the industry.

Both Schneider and Siemens circuit breakers are excellent choices for protecting electrical systems. Schneider excels in versatility and precision engineering, while Siemens is known for its exceptional build quality and innovation. The choice between the two depends on specific needs and preferences, ensuring reliable protection and performance for any electrical system.

✅Miniature Circuit Breakers (MCBs) are essential for protecting electrical circuits from overcurrents and short circuits. There are three primary types of MCBs: Type B, Type C, and Type D. Each type is designed to respond to different levels of electrical surges in various settings.ft starters minimize the initial surge of power during startup by gradually increasing the voltage supply. This controlled power-up process prevents the motor from overheating, reducing the risk of temporary shutdowns and significantly extending the lifespan and durability of the motors.

Type B devices are engineered to trip when fault currents reach 3-5 times the rated current (In). For instance, a 10A Type B device will trip at 30-50A. Type C devices, on the other hand, are designed to trip at fault currents of 5-10 times In, which means a 10A device will trip at 50-100A. Lastly, Type D devices are intended to trip at fault currents of 10-20 times In, so a 10A device will trip at 100-200A.

✅ The product dimensions are (W) 54mm x (H) 85mm x (D) 77.5mm, and it weighs 0.31kg. It adheres to the IEC 60529 standard, offering a degree of protection rated at IP20 and IP40 when enclosed.

 

✅MCB Full Form - Miniature Circuit Breaker

✅Miniature Circuit Breaker

The full form of MCB is Miniature Circuit Breaker. An MCB is a type of electronic switch that operates automatically. It detects issues within a circuit by identifying excessive current flow, providing protection by interrupting the circuit to prevent damage.

✅ Miniature Circuit Breaker (MCB) - Definition, Types, and Uses

A Miniature Circuit Breaker (MCB) is a safety device equipped with an electro-mechanical mechanism that automatically interrupts the flow of excessive current in a circuit. Unlike fuses, MCBs can be reset and reused without manual replacement, enhancing safety and convenience in electrical systems.

Reviews

There are no reviews yet.

Be the first to review “A9F92272”