5SV6016-7KK32
AFDD-MCB-Combination 230V, 6kA, 1+N, C, 32A Compact (1MW)
- Stock status:
- Call for availability
- Manufacturer:
- Siemens
- Product code:
- 5SV6016-7KK32
Main documents
- Product datasheet
- Instruction sheet
- Catalogue
Related products
| Product | |
| Article Number (Market Facing Number) | 5SV6016-7KK32 |
| Product Description | AFDD-MCB-Combination 230V, 6kA, 1+N, C, 32A Compact (1MW) |
| Product family | SENTRON Arc fault detection device |
| Product Lifecycle (PLM) | Active Product |
| Price data | |
| Region Specific PriceGroup / Headquarter Price Group | 13E / 1BA |
| List Price | Show prices |
| Customer Price | Show prices |
| Surcharge for Raw Materials | None |
| Metal Factor | L-A—– |
| Additional Product Information | |||
| EAN | 4001869565071 | ||
| UPC | Not available | ||
| Commodity Code | 85362010 | ||
| LKZ_FDB/ CatalogID | LV10 | ||
| Product Group | 5546 | ||
| Group Code | P310 | ||
| Country of origin | China | ||
| Compliance with the substance restrictions according to RoHS directive | Since: 01.01.2018 | ||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||
| WEEE (2012/19/EU) Take-Back Obligation | yes | ||
| REACH Art. 33 Duty to inform according to the current list of candidates |
Lead monoxide (lead oxide) CAS-No. 1317-36-8 > 0,1 % (w / w) | ||
| SCIP number | 8f222910-1c5f-4883-b496-e624e3940e47 | ||
Product Description
5SV6016-7KK32
The Siemens 5SV6016-7KK32 is a compact Arc Fault Detection Device (AFDD) combined with a Miniature Circuit Breaker (MCB), designed to enhance electrical safety by detecting arc faults while simultaneously providing overload and short-circuit protection. This all-in-one device is ideal for modern residential and commercial installations, combining the protective functions of an AFDD and MCB in a single compact module.

Key Features and Specification
- Device Type: AFDD + MCB Combination (Compact, 1 module width)
- Rated Voltage (Un): 230 V AC
- Rated Current (In):32 A
- Breaking Capacity: 6 kA
- Poles: 1P+N (single-phase with neutral)
- Tripping Characteristic: C-curve (suitable for general loads with moderate inrush currents)
- Mounting: DIN rail

Technical Information
- Number: 5SV6016-7KK32
- EAN: 4001869565101
- Commodity Code: 85362010
- Catalog ID: LV10
- Product Group: 5546
- Group Code: P310
- Lifecycle Status: Active Product
Applications
- Provides arc fault protection, reducing the risk of electrical fires in residential and commercial buildings
- Offers MCB protection against overloads and short circuits
- Ideal for lighting circuits, socket outlets, and mixed-use electrical installations
- Combines space-saving design with advanced electrical safety features
Summary:
The Siemens 5SV6016-7KK32 is a 32 A, 1P+N, C-curve AFDD/MCB combination device with a 6 kA breaking capacity. As part of the SENTRON AFDD product family, it provides comprehensive protection by detecting arc faults while safeguarding against overloads and short circuits. Its compact design ensures reliable and efficient electrical protection in modern installations.
Frequently Asked Questions
What is MCB protection?
✅ MCB (Miniature Circuit Breaker) protects against overloads and short circuits. Overload protection works via a bimetallic strip (thermal operation), while short-circuit protection uses a tripping coil (electromagnetic operation). This ensures electrical safety in homes, businesses, and industries.
What is the rule for installing an SPD?
✅ SPD (Surge Protection Device) connections should be as short as possible to minimize the voltage protection level (Up). The total length of connections to the network and earth should not exceed 50 cm to ensure effective surge protection.
How to Set Up a Surge Protector?
1.Turn off power at the circuit breaker.
2. Remove the old outlet.
3. Connect wires to the new surge-protected outlet per the manufacturer’s instructions.
4. Secure the outlet in the box and replace the cover plate.
5. Restore power and test the outlet.
What is the use of RCCB in Siemens?
✅ Siemens Residual Current Circuit Breakers (RCCBs) protect against electric shock by detecting leakage currents. If the leakage exceeds a set limit, the RCCB immediately disconnects the circuit, ensuring safety from direct or indirect contact with live components.
Where is an RCBO used?
✅ RCBOs (Residual Current Circuit Breakers with Overcurrent protection) are commonly used in various residential, commercial, and industrial applications. Typical use cases include power distribution boards, emergency lighting circuits, HVAC (Heating, Ventilation, and Air Conditioning) systems, socket outlets, and swimming pool equipment. RCBOs are ideal for protecting individual circuits where both earth fault and overcurrent protection are required.
Where to Install RCCB?
✅ RCCBs should be installed in the distribution board (DB box) or circuit breaker panel to protect against current leakages caused by faulty wiring, ageing insulation, or defective appliances.





















Reviews
There are no reviews yet.