3WL1106-2CB46-1AA2
Air circuit breaker SENTRON WL, fixed-mounted version, size I
- Stock status:
- Call for availability
- Manufacturer:
- Siemens
- Product code:
- 3WL1106-2CB46-1AA2
Main documents
- Product datasheet
- Instruction sheet
- Catalogue
Related products
| Product | |
| Article Number | 3WL1106-2CB46-1AA2 |
| Product Description | withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC |
| Product family | 4-pole |
| Product Lifecycle (PLM) | PM400:Phase Out Started |
| PLM Effective Date | Product phase-out since: 01.10.2023 |
| Notes | Successor hint: Successor portfolio 3WA; more information via www.siemens.com/3WA |
| Price data | |
| Price Group | 12M |
| List Price | Show prices |
| Customer Price | Show prices |
| Surcharge for Raw Material | see also metal factor (further details are available on the help page) |
| Metal Factor | LAO—– |
| Additional Product Information | ||
| EAN | Not available | |
| UPC | Not available | |
| Commodity Code | 85362090 | |
| LKZ_FDB/ CatalogID | LV10.1 | |
| Product Group | 3745 | |
| Group Code | P360 | |
| Country of origin | Czech Republic | |
| Compliance with the substance restrictions according to RoHS directive | Given | |
| Product class | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. | |
| WEEE (2012/19/EU) Take-Back Obligation | No | |
| REACH Art. 33 Duty to inform according to the current list of candidates | ||
| SCIP number | Not available | |
Product Description
3WL1106-2CB46-1AA2
The 3WL1106-2CB46-1AA2 is a withdrawable air circuit breaker with a guide frame designed for 4-pole configurations. This circuit breaker provides reliable and adjustable protection for industrial and commercial applications, ensuring safety and ease of maintenance.

Key Features and Specification
- Type: Withdrawable air circuit breaker with guide frame.
- Poles: 4-pole configuration for enhanced system flexibility.
- Frame Size: Size I.
- Rated Current (In): 630A at up to 690V.
- Rated Voltage: Up to 690V AC, 50/60Hz.
- Breaking Capacity (Icu): 55kA at 500V.
- Overcurrent Release: ETU 25 LSI with adjustable protection range of 0.4 to 1 x In.
Operating Mechanism:
- Type: Manual operating mechanism with storage for reliable and user-friendly operation.
- Mechanical Request: Integrated for enhanced manual functionality.
Additional Features:
- Connection: Rear horizontal connection for secure installation.
Auxiliary Releases:
- 1st Auxiliary Release: Not included.
- 2nd Auxiliary Release: Not included.
- Auxiliary Contacts: 2NO+2NC configuration for monitoring and control integration.
Product Lifecycle:
- Lifecycle Status: PM400 – Phase-out started as of October 1, 2023.
- Replacement Recommendation: Siemens recommends transitioning to the advanced 3WA series for continued support and enhanced functionality.
Product Details:
- Product Family: 4-pole.
- Commodity Code: 85362090.
- Catalog ID: LV10.1.
- Product Group: 3745.
- Group Code: P360.
Features and Benefits:
Withdrawable Design with Guide Frame:
- Facilitates easy maintenance, inspections, and replacement tasks, minimizing downtime.
Advanced Overcurrent Protection:
- Equipped with ETU 25 LSI, offering precise, adjustable settings suitable for a range of electrical systems.
High Breaking Capacity:
- Rated for fault currents up to 55kA at 500V, ensuring robust protection in high-demand environments.
Pole Configuration:
- Provides enhanced safety and operational flexibility, especially in systems requiring neutral protection.
Auxiliary Contact Configuration:
- Includes 2NO+2NC for seamless integration into monitoring and control systems.
Applications:
Industrial Power Distribution:
- Ideal for use in factories, manufacturing plants, and critical facilities requiring high reliability.
Maintenance-Friendly Systems:
- Withdrawable design simplifies regular maintenance and enhances system uptime.
Advanced Protection Needs:
- Adjustable overcurrent settings make it suitable for diverse operational conditions.
Summary:
The Siemens 3WL1106-2CB46-1AA2 withdrawable circuit breaker with a guide frame is a dependable and flexible solution for industrial and commercial power systems. Its 4-pole design, adjustable ETU 25 LSI protection, and withdrawable mechanism make it ideal for critical power applications. As this model is being phased out, Siemens advises transitioning to the 3WA series for future-proof performance and support.
Frequently Asked Questions
What is the Range of Siemens Air Circuit Breakers (ACB)?
✅ Siemens Air Circuit Breakers (ACBs) are essential components for protection in low-voltage systems (LV) with advanced features for high breaking capacities. The Siemens ACB product lines, including the 3WL and 3WT series, are designed to meet a wide range of industrial needs.
Voltage Range: Siemens ACBs support systems with voltages up to 690V.
Current Rating: They are available with current ratings from 630 A up to 6300 A, accommodating various applications.
Key Features: Siemens ACBs offer exceptional performance with multiple breaking capacities and intelligent monitoring capabilities, making them reliable choices for demanding environments.
This flexibility in ratings and series options ensures Siemens ACBs are suitable for diverse low-voltage protection applications.
Which is Better: ACB or MCCB?
✅ Current Rating: ACBs are designed for higher current ratings than MCCBs, making them ideal for circuits with larger current demands.
✅ Adjustable Tripping: MCCBs offer adjustable tripping thresholds, which makes them versatile and suitable for a variety of circuit applications. This flexibility can give MCCBs an advantage in systems where different levels of protection are required.
In summary, ACBs are often preferred for high-current circuits, while MCCBs provide flexibility and adaptability in a range of applications. Each type has its strengths depending on the specific needs of the electrical system.
When Should You Use an ACB (Air Circuit Breaker)?
✅ Air Circuit Breakers (ACBs) are ideal for high-voltage applications, such as substations and power transmission systems, where they offer dependable protection by effectively interrupting heavy fault currents. Their robust design makes them a top choice for safeguarding critical electrical systems that require high fault-clearing capabilities.
What is the Purpose of a WL Circuit Breaker?
✅ The Siemens WL power circuit breaker is designed for low-voltage switchgear and switchboard applications, offering essential protection against short circuits and faults to prevent electrical damage or fire hazards. Commonly used as incoming-feeder, coupler, and outgoing-feeder circuit breakers, WL circuit breakers serve a wide range of applications in industrial, commercial, and infrastructure settings. They are a reliable choice for ensuring the safety and efficiency of electrical installations.
Are Siemens WL Circuit Breakers 100% Rated?
✅ Yes, Siemens WL circuit breakers are 100% rated, meaning they are designed for continuous operation at their full current rating without requiring external heat sinks. These breakers are engineered to meet the rigorous demands of standard industrial and commercial applications, ensuring reliable performance and protection for continuous, high-current usage.

















Reviews
There are no reviews yet.