Product Catalogue
Download Product Catalogue
100% Genuine Products
Supplier of industrial electrical products
1 year warranty
The products have a warranty
A9F73303
Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 3A, B curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
- Stock status:
- In stock
- Manufacturer:
- Schneider
- Product code:
- A9F73303
Main documents
- Product datasheet
- Instruction sheet
- Catalogue
Device application | Distribution |
---|---|
Range | Acti9 |
Product name | Acti9 iC60 |
Product or component type | Miniature circuit-breaker |
Device short name | IC60N |
poles description | 3P |
Number of protected poles | 3 |
[In] rated current | 3 A |
network type | AC DC |
Trip unit technology | Thermal-magnetic |
Curve code | B |
Breaking capacity | 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 |
Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
Standards | EN 60898-1 IEC 60898-1 EN 60947-2 IEC 60947-2 |
network frequency | 50/60 Hz |
---|---|
Magnetic tripping limit | 4 x In +/- 20 % |
[Ics] rated service breaking capacity | 50 kA 100 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz 25 kA 100 % conforming to EN 60947-2 – 440 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz 25 kA 100 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 – 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 – 125…180 V DC 10 kA 100 % conforming to EN 60947-2 – 125…180 V DC |
Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
Contact position indicator | Yes |
Control type | Toggle |
local signalling | Trip indicator |
mounting mode | Fixed |
mounting support | DIN rail |
Comb busbar and distribution block compatibility | Top or bottom: YES |
9 mm pitches | 6 |
Height | 85 mm |
Width | 54 mm |
Depth | 78.5 mm |
Net weight | 0.375 kg |
Colour | White |
Mechanical durability | 20000 cycles |
Electrical durability | 10000 cycles |
Connections – terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
Wire stripping length | 14 mm for top or bottom connection |
Tightening torque | 2 N.m top or bottom |
Earth-leakage protection | Separate block |
IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
---|---|
Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
Overvoltage category | IV |
Tropicalisation | 2 conforming to IEC 60068-1 |
Relative humidity | 95 % at 55 °C |
Operating altitude | 0…2000 m |
Ambient air temperature for operation | -35…70 °C |
Ambient air temperature for storage | -40…85 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 5.500 cm |
Package 1 Width | 7.500 cm |
Package 1 Length | 9.500 cm |
Package 1 Weight | 341.000 g |
Unit Type of Package 2 | BB1 |
Number of Units in Package 2 | 4 |
Package 2 Height | 8.000 cm |
Package 2 Width | 10.000 cm |
Package 2 Length | 22.500 cm |
Package 2 Weight | 1.407 kg |
Unit Type of Package 3 | S03 |
Number of Units in Package 3 | 44 |
Package 3 Height | 30.000 cm |
Package 3 Width | 30.000 cm |
Package 3 Length | 40.000 cm |
Package 3 Weight | 15.868 kg |
Product Description
Schneider Electric
Schneider Electric is a multinational corporation specializing in energy management and automation solutions. With operations in over 100 countries, the company offers a wide range of products and services for various industries, including residential, commercial, and industrial.
Schneider Electric is focused on sustainability and innovation, aiming to help their customers manage energy efficiently and reduce their environmental impact.
Schneider Miniature Circuit Breaker
Schneider Miniature Circuit Breakers (MCBs) are advanced safety devices designed to protect electrical circuits from overloads and short circuits. With an electro-mechanical mechanism, these MCBs automatically disconnect the circuit when excessive current is detected, ensuring reliable protection and preventing potential damage. Schneider MCBs can be easily reset and reused, offering a practical and efficient solution for residential, commercial, and industrial electrical systems.
MCB Breaker
An MCB breaker, or Miniature Circuit Breaker, is a crucial safety device in electrical systems designed to protect circuits from overloads and short circuits. Featuring an electro-mechanical mechanism, an MCB breaker automatically trips to disconnect the circuit when excessive current is detected. Unlike traditional fuses, MCB breakers can be easily reset and reused, providing enhanced safety, convenience, and cost-effectiveness for residential, commercial, and industrial applications.
A9F73303
The Acti9 iC60N (model A9F73303) is a high-performance low voltage miniature circuit breaker (MCB) designed for optimal protection in various electrical circuits. This 3-pole (3P) circuit breaker features a 3A rated current and a B curve tripping characteristic, ideal for residential and light commercial applications where low inrush currents are present.
Key Features and Specifications:
- Type: Miniature Circuit Breaker (MCB)
- Poles: 3P (Three Poles)
- Rated Current: 3A
- Tripping Curve: B curve (sensitive to short-circuit currents)
Short Circuit Breaking Capacity:
- 50kA at 220VAC to 240VAC: Conforming to EN/IEC 60947-2 standard.
- 6kA at 400VAC: Conforming to EN/IEC 60898-1 standard, ensuring robust protection against short circuits and overloads.
Compliance and Standards:
- Standards: Fully compliant with both industrial EN/IEC 60898-1 and residential EN/IEC 60947-2 standards, making it versatile for a wide range of applications.
Innovative Features:
- VisiTrip Indicator: Clearly shows the faulty circuit, reducing troubleshooting time.
- VisiSafe Green Strip: Ensures visible confirmation of the physical opening of contacts, allowing safe downstream maintenance.
- Fast Closing Mechanism: Independent of manual operation, enhancing durability and reliability.
Durability:
- Electrical Endurance: Up to 10,000 cycles.
- Mechanical Endurance: Up to 20,000 cycles.
Electrical Specifications:
- Rated Insulation Voltage (Ui): 500VAC.
- Limitation Class: Class 3 according to EN/IEC 60898-1, improving downstream circuit protection.
Installation:
- Mounting: Can be easily clipped onto a DIN rail for modular installations.
- Width: 6 pitches (9mm per pitch).
- Color: White (RAL9003).
Protection and Safety:
- Degree of Protection: IP20 at terminals; IP40 when installed in an enclosure according to IEC 60529.
- Operating Temperature: -35°C to 70°C.
- Storage Temperature: -40°C to 85°C.
This 3A Acti9 iC60N MCB is designed for reliable protection of electrical circuits, combining advanced safety features with compliance to international standards, making it an ideal choice for a wide range of electrical installations.
Frequently Asked Questions
Is Schneider Circuit Breaker Good?
Schneider Electric circuit breakers are a top choice for protecting electrical systems from overloads and short circuits. Renowned for their superior quality, reliability, and safety, Schneider Electric offers a wide range of products to meet diverse needs and requirements.
✅ For pricing, reviews, and purchasing Schneider Electric circuit breakers, you can contact the GeeTech group.
Which is Better: Schneider or Siemens Circuit Breakers?
When comparing Schneider and Siemens circuit breakers, both brands offer unique strengths and advantages, making them top choices in the industry.
✅ Both Schneider and Siemens circuit breakers are excellent choices for protecting electrical systems. Schneider excels in versatility and precision engineering, while Siemens is known for its exceptional build quality and innovation. The choice between the two depends on specific needs and preferences, ensuring reliable protection and performance for any electrical system.
What are the three types of miniature circuit breaker?
✅Miniature Circuit Breakers (MCBs) are essential for protecting electrical circuits from overcurrents and short circuits. There are three primary types of MCBs: Type B, Type C, and Type D. Each type is designed to respond to different levels of electrical surges in various settings.ft starters minimize the initial surge of power during startup by gradually increasing the voltage supply. This controlled power-up process prevents the motor from overheating, reducing the risk of temporary shutdowns and significantly extending the lifespan and durability of the motors.
What's the difference between type B and C MCBs?
✅Type B devices are engineered to trip when fault currents reach 3-5 times the rated current (In). For instance, a 10A Type B device will trip at 30-50A. Type C devices, on the other hand, are designed to trip at fault currents of 5-10 times In, which means a 10A device will trip at 50-100A. Lastly, Type D devices are intended to trip at fault currents of 10-20 times In, so a 10A device will trip at 100-200A.
What size is a Schneider 3 pole MCB?
✅ The product dimensions are (W) 54mm x (H) 85mm x (D) 77.5mm, and it weighs 0.31kg. It adheres to the IEC 60529 standard, offering a degree of protection rated at IP20 and IP40 when enclosed.
What is the Full Name of MCBs?
✅MCB Full Form - Miniature Circuit Breaker
✅Miniature Circuit Breaker
The full form of MCB is Miniature Circuit Breaker. An MCB is a type of electronic switch that operates automatically. It detects issues within a circuit by identifying excessive current flow, providing protection by interrupting the circuit to prevent damage.
What Are Miniature Circuit Breakers?
✅ Miniature Circuit Breaker (MCB) - Definition, Types, and Uses
A Miniature Circuit Breaker (MCB) is a safety device equipped with an electro-mechanical mechanism that automatically interrupts the flow of excessive current in a circuit. Unlike fuses, MCBs can be reset and reused without manual replacement, enhancing safety and convenience in electrical systems.
Reviews
There are no reviews yet.