{"id":18171,"date":"2024-05-11T08:35:45","date_gmt":"2024-05-11T12:35:45","guid":{"rendered":"https:\/\/geetech.com.tr\/?post_type=product&#038;p=18171"},"modified":"2025-10-30T07:14:15","modified_gmt":"2025-10-30T11:14:15","slug":"31336","status":"publish","type":"product","link":"https:\/\/geetech.com.tr\/tr\/product\/31336\/","title":{"rendered":"31336"},"content":{"rendered":"<h2 data-start=\"0\" data-end=\"358\">31336<\/h2>\n<p data-start=\"0\" data-end=\"358\">The Schneider Electric <strong data-start=\"23\" data-end=\"64\">Compact INS1600 (Product code: 31336)<\/strong> is a <strong data-start=\"70\" data-end=\"114\">3-pole non-automatic switch-disconnector<\/strong> engineered for high-current applications, providing reliable isolation and current interruption in both AC and DC networks. It features a black rotary handle for easy operation and complies with <strong data-start=\"310\" data-end=\"325\">IEC 60947-1<\/strong> and <strong data-start=\"330\" data-end=\"345\">IEC 60947-3<\/strong> standards.<\/p>\n<div tabindex=\"-1\" role=\"button\" aria-label=\"schneider contactor. This is a keyword you provided.\" aria-expanded=\"false\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-18078 size-full\" src=\"https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/04\/switch-disconnector-schneider.png\" alt=\"31334 - schneider switch disconnector\" width=\"1000\" height=\"563\" title=\"\" srcset=\"https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/04\/switch-disconnector-schneider.png 1000w, https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/04\/switch-disconnector-schneider-150x84.png 150w, https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/04\/switch-disconnector-schneider-300x169.png 300w, https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/04\/switch-disconnector-schneider-768x432.png 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<h2 data-start=\"360\" data-end=\"379\"><strong data-start=\"360\" data-end=\"377\">Key Features:<\/strong><\/h2>\n<ul data-start=\"380\" data-end=\"1754\">\n<li data-start=\"380\" data-end=\"568\">\n<p data-start=\"382\" data-end=\"414\"><strong data-start=\"382\" data-end=\"412\">Rated Operational Current:<\/strong><\/p>\n<ul data-start=\"417\" data-end=\"568\">\n<li data-start=\"417\" data-end=\"458\">\n<p data-start=\"419\" data-end=\"458\">AC21B \/ AC22B: 1600 A at 220\u2013690 V AC<\/p>\n<\/li>\n<li data-start=\"461\" data-end=\"510\">\n<p data-start=\"463\" data-end=\"510\">AC23A \/ AC21A \/ AC22A: 1250 A at 220\u2013690 V AC<\/p>\n<\/li>\n<li data-start=\"513\" data-end=\"568\">\n<p data-start=\"515\" data-end=\"568\">DC-21\/22\/23: 1600 A at 125 V DC (2 poles in series)<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"569\" data-end=\"586\">\n<p data-start=\"571\" data-end=\"586\"><strong data-start=\"571\" data-end=\"581\">Poles:<\/strong> 3P<\/p>\n<\/li>\n<li data-start=\"587\" data-end=\"641\">\n<p data-start=\"589\" data-end=\"641\"><strong data-start=\"589\" data-end=\"619\">Rated Operational Voltage:<\/strong> 690 V AC \/ 125 V DC<\/p>\n<\/li>\n<li data-start=\"642\" data-end=\"685\">\n<p data-start=\"644\" data-end=\"685\"><strong data-start=\"644\" data-end=\"673\">Rated Insulation Voltage:<\/strong> 1000 V AC<\/p>\n<\/li>\n<li data-start=\"686\" data-end=\"732\">\n<p data-start=\"688\" data-end=\"732\"><strong data-start=\"688\" data-end=\"724\">Rated Impulse Withstand Voltage:<\/strong> 12 kV<\/p>\n<\/li>\n<li data-start=\"733\" data-end=\"831\">\n<p data-start=\"735\" data-end=\"831\"><strong data-start=\"735\" data-end=\"775\">Short-Circuit Making Capacity (Icm):<\/strong> 75 kA alone, 330 kA with upstream breaker at 690 V AC<\/p>\n<\/li>\n<li data-start=\"832\" data-end=\"905\">\n<p data-start=\"834\" data-end=\"905\"><strong data-start=\"834\" data-end=\"873\">Short-Time Withstand Current (Icw):<\/strong> Up to 50 kA depending on duty<\/p>\n<\/li>\n<li data-start=\"906\" data-end=\"952\">\n<p data-start=\"908\" data-end=\"952\"><strong data-start=\"908\" data-end=\"934\">Thermal Current (Ith):<\/strong> 1600 A at 60\u202f\u00b0C<\/p>\n<\/li>\n<li data-start=\"953\" data-end=\"1009\">\n<p data-start=\"955\" data-end=\"1009\"><strong data-start=\"955\" data-end=\"972\">Control Type:<\/strong> Direct front rotary handle (black)<\/p>\n<\/li>\n<li data-start=\"1010\" data-end=\"1082\">\n<p data-start=\"1012\" data-end=\"1082\"><strong data-start=\"1012\" data-end=\"1042\">Suitability for Isolation:<\/strong> Yes, with positive contact indication<\/p>\n<\/li>\n<li data-start=\"1083\" data-end=\"1110\">\n<p data-start=\"1085\" data-end=\"1110\"><strong data-start=\"1085\" data-end=\"1106\">Pollution Degree:<\/strong> 3<\/p>\n<\/li>\n<li data-start=\"1111\" data-end=\"1175\">\n<p data-start=\"1113\" data-end=\"1175\"><strong data-start=\"1113\" data-end=\"1126\">Mounting:<\/strong> Fixed on rail or plate, front-side connections<\/p>\n<\/li>\n<li data-start=\"1176\" data-end=\"1247\">\n<p data-start=\"1178\" data-end=\"1247\"><strong data-start=\"1178\" data-end=\"1213\">Maximum Power Handling (AC-23):<\/strong> 400\u2013900 kW depending on voltage<\/p>\n<\/li>\n<li data-start=\"1248\" data-end=\"1316\">\n<p data-start=\"1250\" data-end=\"1316\"><strong data-start=\"1250\" data-end=\"1265\">Rated Duty:<\/strong> Uninterrupted, Intermittent duty class 120 \u2013 60%<\/p>\n<\/li>\n<li data-start=\"1317\" data-end=\"1359\">\n<p data-start=\"1319\" data-end=\"1359\"><strong data-start=\"1319\" data-end=\"1345\">Mechanical Durability:<\/strong> 3000 cycles<\/p>\n<\/li>\n<li data-start=\"1360\" data-end=\"1452\">\n<p data-start=\"1362\" data-end=\"1390\"><strong data-start=\"1362\" data-end=\"1388\">Electrical Durability:<\/strong><\/p>\n<ul data-start=\"1393\" data-end=\"1452\">\n<li data-start=\"1393\" data-end=\"1423\">\n<p data-start=\"1395\" data-end=\"1423\">AC-21A\/22A\/23A: 500 cycles<\/p>\n<\/li>\n<li data-start=\"1426\" data-end=\"1452\">\n<p data-start=\"1428\" data-end=\"1452\">AC-21B\/22B: 100 cycles<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"1453\" data-end=\"1484\">\n<p data-start=\"1455\" data-end=\"1484\"><strong data-start=\"1455\" data-end=\"1476\">Connection Pitch:<\/strong> 70 mm<\/p>\n<\/li>\n<li data-start=\"1485\" data-end=\"1533\">\n<p data-start=\"1487\" data-end=\"1533\"><strong data-start=\"1487\" data-end=\"1510\">Dimensions (HxWxD):<\/strong> 300 x 340 x 146.5 mm<\/p>\n<\/li>\n<li data-start=\"1534\" data-end=\"1559\">\n<p data-start=\"1536\" data-end=\"1559\"><strong data-start=\"1536\" data-end=\"1551\">Net Weight:<\/strong> 14 kg<\/p>\n<\/li>\n<li data-start=\"1560\" data-end=\"1614\">\n<p data-start=\"1562\" data-end=\"1614\"><strong data-start=\"1562\" data-end=\"1587\">Standards Compliance:<\/strong> IEC 60947-1, IEC 60947-3<\/p>\n<\/li>\n<li data-start=\"1615\" data-end=\"1648\">\n<p data-start=\"1617\" data-end=\"1648\"><strong data-start=\"1617\" data-end=\"1636\">Certifications:<\/strong> KEMA-KEUR<\/p>\n<\/li>\n<li data-start=\"1649\" data-end=\"1686\">\n<p data-start=\"1651\" data-end=\"1686\"><strong data-start=\"1651\" data-end=\"1672\">IP\/IK Protection:<\/strong> IP40 \/ IK07<\/p>\n<\/li>\n<li data-start=\"1687\" data-end=\"1754\">\n<p data-start=\"1689\" data-end=\"1754\"><strong data-start=\"1689\" data-end=\"1713\">Ambient Temperature:<\/strong> Operation -25\u202670\u202f\u00b0C, Storage -50\u202685\u202f\u00b0C<\/p>\n<\/li>\n<\/ul>\n<\/div>\n<div tabindex=\"-1\" role=\"button\" aria-label=\"schneider contactor. This is a keyword you provided.\" aria-expanded=\"false\">\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-18172 size-full\" src=\"https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/05\/31336.webp\" alt=\"31336\" width=\"600\" height=\"568\" title=\"\" srcset=\"https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/05\/31336.webp 600w, https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/05\/31336-150x142.webp 150w, https:\/\/geetech.com.tr\/wp-content\/uploads\/2024\/05\/31336-300x284.webp 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/p>\n<article class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [&amp;:has([data-writing-block])&gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" tabindex=\"-1\" data-turn-id=\"request-69030dd8-ca2c-8328-959e-02dbbcb4d2b8-6\" data-testid=\"conversation-turn-36\" data-scroll-anchor=\"true\" data-turn=\"assistant\">\n<div class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] thread-sm:[--thread-content-margin:--spacing(6)] thread-lg:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\">\n<div class=\"[--thread-content-max-width:40rem] thread-lg:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\">\n<div class=\"flex max-w-full flex-col grow\">\n<div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+&amp;]:mt-1\" dir=\"auto\" data-message-author-role=\"assistant\" data-message-id=\"31e76b7f-e52e-4deb-8ec2-0174ac2269be\" data-message-model-slug=\"gpt-5-mini\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\">\n<div class=\"markdown prose dark:prose-invert w-full break-words dark markdown-new-styling\">\n<h3 data-start=\"1756\" data-end=\"1775\"><strong data-start=\"1756\" data-end=\"1773\">Applications:<\/strong><\/h3>\n<ul data-start=\"1776\" data-end=\"1990\">\n<li data-start=\"1776\" data-end=\"1856\">\n<p data-start=\"1778\" data-end=\"1856\">Isolation and switching in industrial low-voltage power distribution systems<\/p>\n<\/li>\n<li data-start=\"1857\" data-end=\"1908\">\n<p data-start=\"1859\" data-end=\"1908\">Safe current interruption in AC and DC networks<\/p>\n<\/li>\n<li data-start=\"1909\" data-end=\"1990\">\n<p data-start=\"1911\" data-end=\"1990\">High-current switching for commercial and industrial electrical installations<\/p>\n<\/li>\n<\/ul>\n<h2 data-start=\"1992\" data-end=\"2212\"><strong data-start=\"1992\" data-end=\"2004\">Summary:<\/strong><\/h2>\n<p data-start=\"1992\" data-end=\"2212\" data-is-last-node=\"\" data-is-only-node=\"\">The <strong data-start=\"2011\" data-end=\"2030\">Compact INS1600<\/strong> provides high operational reliability, positive contact indication for safety, and robust current interruption performance, making it suitable for demanding electrical environments.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/article>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"main-product-info__description sc-pes-main-product-info\" style=\"font-size: 18px;\">switch disconnector, Compact INS1600 , 1600 A, standard version with black rotary handle, 3 poles<\/h2>\n","protected":false},"featured_media":18172,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[1121,677,1130],"product_tag":[1143,1145,1133,1135,1144,1136,1050,1134],"class_list":{"0":"post-18171","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-circuit-breakers-and-switches","7":"product_cat-schneider-products","8":"product_cat-switch-disconnectors-and-fuses","9":"product_tag-1143","10":"product_tag-31336-schneider","11":"product_tag-fuse-switch","12":"product_tag-fuse-switch-disconnector","13":"product_tag-schneider-31336","14":"product_tag-schneider-isolator-switch","15":"product_tag-switch-disconnector","16":"product_tag-switch-fuse-isolator","18":"first","19":"instock","20":"shipping-taxable","21":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/product\/18171","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/comments?post=18171"}],"version-history":[{"count":4,"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/product\/18171\/revisions"}],"predecessor-version":[{"id":37642,"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/product\/18171\/revisions\/37642"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/media\/18172"}],"wp:attachment":[{"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/media?parent=18171"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/product_brand?post=18171"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/product_cat?post=18171"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/geetech.com.tr\/tr\/wp-json\/wp\/v2\/product_tag?post=18171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}