All Categories

Product Catalogue

Download Product Catalogue

100% Genuine Products

Supplier of industrial electrical products

1 year warranty

The products have a warranty

METSEPM2130

5/5 - (4 votes)

EasyLogic PM2130, Power & Energy meter, up to 31stH, LED, RS485, class 0.5S

Main documents

Main
RangeEasyLogic
Product nameEasyLogic PM2100
Device short namePM2130
product or component typePower meter
Complementary
Device applicationSub billing
Power monitoring
Power quality analysisTotal harmonic distortion
up to the 31st harmonic
Type of measurementApparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy total
Metering typePeak demand currents
Active power P, P1, P2, P3
Demand power P, Q, S
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Active, reactive, apparent energy (signed, four quadrant)
Voltage U, U21, U32, U13, V, V1, V2, V3
Current I, I1, I2, I3
Calculated neutral current
Unbalance current
Peak demand power PM, QM, SM
Accuracy classClass 1 reactive energy conforming to IEC 62053-24
Class 0.5S active energy conforming to IEC 62053-22
Class 5 harmonic distorsion (I THD & U THD)
Measurement accuracyApparent power +/- 0.5 %
Active energy +/- 0.5 %
Reactive energy +/- 1 %
Active power +/- 0.5 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range45…65 Hz
[Us] rated supply voltage80…277 V AC 45…65 Hz +/- 10 %
100…277 V DC +/- 10 %
Network frequency50 Hz
60 Hz
Ride-through time50 ms 120 V AC typical
50 ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current1 A
5 A
Maximum power consumption in VA8 VA at 277 V AC
Maximum power consumption in W3.3 W (power lines (AC))
3.3 W at 277 V (power lines (DC))
input impedanceCurrent (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settingsProtected by access code
Display type7 segments LED
Display colourRed
Messages display capacity3 fields of 4 characters
Display digits12 digit(s) – 14.2 mm in height
Demand intervalsConfigurable from 1 to 60 min
Information displayedDemand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type3 x button
Local signallingRed LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Number of inputs0
Number of outputs0
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V
Communication port supportScrew terminal block: RS485
Data recordingPower logs
Time stamping
Energy consumption logs
Min/max for 8 parameters
Function availableReal time clock
Sampling rate64 samples/cycle
CybersecurityEnable/disable communication ports
communication serviceRemote monitoring
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
mounting modeClip-on
Mounting positionVertical
Mounting supportFramework
Provided equipment1 x installation guide
Measurement categoryCategory III 480 V
Category II 480…600 V
Electrical insulation classClass II
Double insulation
Flame retardanceV-0 conforming to UL 94
Connections – terminalsCurrent transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4
MaterialPolycarbonate
Width96 mm
DepthTotal : 76.09 mm
Embedded : 61.64 mm
Height96 mm
net weight300 g
Compatibility codePM2130
Environment
Service life7 year(s)
IP degree of protectionIP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity5…95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10…60 °C
ambient air temperature for storage-25…70 °C
Operating altitude<= 2000 m
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Overvoltage categoryIII
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.500 cm
Package 1 Width12.000 cm
Package 1 Length12.500 cm
Package 1 Weight407.000 g
Unit Type of Package 2S03
Number of Units in Package 218
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.726 kg
Product Description

Schneider Power Meters

Frequently Asked Questions

Push button switches can be classified as either normally open (NO) or normally closed (NC). Normally open (NO) switches, also known as "OFF" position switches, complete the circuit when actuated. In contrast, normally closed (NC) switches, or "ON" position switches, break the circuit when actuated. Understanding the difference between NO and NC push button switches is crucial for selecting the right type for your application, whether it's for industrial machinery, control panels, or electronic devices.

Push button switches come in two main types: single-pole and double-pole switches. The single-pole switch is the most common type, featuring a control device with a single input source and a single output source. This basic design makes single-pole switches ideal for a wide range of applications. Double-pole switches, on the other hand, have two input sources and two output sources, offering more complex control capabilities for advanced electrical systems.

No, a push button is not an analog sensor. An analog sensor provides a continuous output signal that varies in proportion to the measured quantity. In contrast, a push button provides a discrete output signal that changes state from one level to another when the button is pressed or released. This distinction makes push buttons ideal for applications requiring simple on/off control, unlike analog sensors that are used for more complex, variable measurements.

✅ A push button consists of several key components:

1. Button Actuator: This is the part you physically press. It is connected to an internal mechanism within the switch.

2. Contacts: Push button switches contain one or more sets of contacts, typically made from conductive materials like metal. In their default state, these contacts are separated.

When the button actuator is pressed, it moves the contacts together to complete an electrical circuit. This simple yet effective design is what makes push buttons reliable for various applications, from industrial machinery to everyday electronic devices.

A push button is a digital sensor. Unlike analog sensors, which provide a continuous range of values, digital sensors like push buttons have only two states: on or off. For example, when you press a push button, it changes from off to on, providing a discrete signal. Similarly, a digital light sensor can detect whether it is dark or bright, also giving a binary output. This clear distinction makes push buttons ideal for simple, straightforward control in various applications.

Değerlendirmeler

Henüz değerlendirme yapılmadı.

“METSEPM2130” için yorum yapan ilk kişi siz olun

E-posta adresiniz yayınlanmayacak. Gerekli alanlar * ile işaretlenmişlerdir

Start typing to see products you are looking for.