Product Catalogue
Download Product Catalogue
100% Genuine Products
Supplier of industrial electrical products
1 year warranty
The products have a warranty
IMDIFL12C
Vigilohm – self-isolation locator – 12 channels – 110-440VAC/DC
- Stock status:
- In stock
- Manufacturer:
- Schneider
- Product code:
- IMDIFL12C
Main documents
Range | Vigilohm |
---|---|
Name of the device | IFL12C |
Product type or equipment | Insulation fault locator |
Application | Standard environment application Marine application |
Type of electrical circuit | Moderately or slightly disturbed network |
Type of electrical circuit | Power circuit |
Grounding diagram | IT |
User language | Portuguese Russian Chinese French Spanish Italian German English |
Network voltage | 0…1000 V – AC at 45…65 Hz 0…1000 V – DC |
---|---|
Number of channels | 12 |
Local signage | Yellow indicator light: insulation fault Yellow indicator light flash: communication Green/red indicator light: product status Green indicator light: satisfactory insulation Yellow indicator light flash: transient error |
Threshold adjustment | Alarm: high, medium, low |
Alarm per channel | Alarm threshold: common to all lines |
Response time | <= 5 sec |
Auxiliary supply voltage | 100 to 440 V DC +/- 15% 100 to 440 V AC 45…65 Hz +/- 15% |
Power consumed in VA | 26VA |
Power consumed in W | 10W |
Function test | Automatic test at startup and every 5 hours Remote test Manual |
Output contact | 1F/O standard or faultless |
Breaking capacity | 250 V – AC at 6 A 48 V – DC at 1 A |
Communication protocol | Modbus |
Communications port | RS485 |
Display type | Digital display |
Installation mode | Suspended Snap-on |
Mounting bracket | DIN Rail Panel |
Mounting position | Horizontal Vertical |
Connection method | Power supply: removable screw terminal block 0.2…2.5 mm² Output relay: removable screw terminal block 0.2…2.5 mm² Toroid inputs: removable screw terminal block 0.2…1.5 mm² Communication: removable screw terminal block 0.2… 2.5 mm² 2…2.5 mm² |
Matter | Thermoplastic |
Overvoltage category | III |
Product weight | 0.5kg |
Cutout dimensions | 92 x 104mm |
Height | 110mm |
Width | 108mm |
Depth | 59mm |
Degree of IP protection | Housing: IP20 Front: IP54 |
---|---|
Environment Characteristic | Exposure to damp heat when not in operation conforming to IEC 60068-2-30 Exposure to damp heat when in operation conforming to IEC 60068-2-56 Salt mist conforming to IEC 60068-2-52 |
Operating altitude | <= 3000 m |
Degree of pollution | 2 |
Relative humidity | 5…92% |
Installation type | Interior |
Standards | IEC 60364-4-41 IEC 61010-1 IEC 60364-5-51 IEC 61557-9 |
Product certifications | EAC CE DNV-GL UL cULus |
Ambient operating temperature | -25…55°C |
Ambient storage temperature | -40…85°C |
Packaging type 1 | PCE |
---|---|
Number of products in packaging 1 | 1 |
Package Height 1 | 9.7cm |
Package width 1 | 18.2cm |
Package length 1 | 13.5cm |
Package weight 1 | 550.0g |
Packaging type 2 | S03 |
Number of products in packaging 2 | 8 |
Package Height 2 | 30.0 cm |
Package width 2 | 30.0 cm |
Package length 2 | 40.0 cm |
Package weight 2 | 5.2kg |
Product Description
Schneider Electric
Schneider Electric is a multinational corporation specializing in energy management and automation solutions. With operations in over 100 countries, the company offers a wide range of products and services for various industries, including residential, commercial, and industrial.
Schneider Electric is focused on sustainability and innovation, aiming to help their customers manage energy efficiently and reduce their environmental impact.
Schneider Power Monitoring and Control
Schneider Electric offers a comprehensive suite of power monitoring and control solutions designed to enhance energy efficiency, improve system reliability, and reduce operational costs. These solutions include advanced hardware, software, and integrated systems that provide real-time monitoring, analysis, and control of electrical power systems.
Schneider Insulation Monitors
Schneider Electric offers a range of insulation monitors designed to ensure the safety and reliability of electrical systems by continuously monitoring the insulation resistance. These devices are crucial in preventing electrical hazards, reducing downtime, and maintaining operational efficiency, particularly in critical environments like hospitals, industrial plants, and data centers.
Key Features of Schneider Insulation Monitors
1. Continuous Monitoring
Insulation monitors provide real-time surveillance of insulation resistance in electrical systems.
They detect insulation faults early, allowing for timely maintenance and preventing potential electrical failures.
2. Alarm and Notification Systems
These monitors are equipped with alarm systems that alert operators to insulation degradation or faults.
Alarms can be visual, auditory, or sent via communication interfaces to central monitoring systems.
3. Advanced Measurement Techniques
Schneider’s insulation monitors use advanced algorithms to accurately measure insulation resistance, even in complex electrical networks.
They can differentiate between temporary disturbances and genuine insulation issues.
Specific Models and Solutions
Vigilohm Series
Vigilohm IM400/IM400H:
These are robust insulation monitoring devices designed for IT (unearthed) systems.
IM400H specifically caters to hospital environments, ensuring patient safety by continuously monitoring the insulation resistance of medical IT systems.
Features include:
Real-time monitoring with high accuracy.
Advanced alarm management with customizable thresholds.
Communication capabilities for integration with building management systems.
Vigilohm IM4000:
Designed for industrial applications, the IM4000 offers comprehensive monitoring of large and complex electrical systems.
It provides detailed diagnostics and can be integrated with other monitoring systems for enhanced operational insights.
Benefits
Enhanced Safety:
Continuous insulation monitoring helps in preventing electrical shocks and fires caused by insulation failures.
Critical in environments where electrical safety is paramount, such as hospitals and industrial plants.
Operational Efficiency:
Early detection of insulation faults allows for planned maintenance, reducing unplanned downtime.
Ensures continuous operation of critical systems without unexpected interruptions.
Compliance and Standards:
Schneider’s insulation monitors help organizations comply with electrical safety standards and regulations.
They support adherence to international standards such as IEC 61557-8 for insulation monitoring devices.
Integration and Communication:
These devices can be easily integrated into broader energy management and building automation systems.
Support for various communication protocols (e.g., Modbus) ensures seamless connectivity and data exchange.
Applications of Insulation Monitors
Healthcare:
Ensures the safety and reliability of electrical systems in hospitals, preventing insulation failures that could jeopardize patient safety.
Industrial Plants:
Maintains operational efficiency by monitoring the insulation resistance of critical machinery and electrical systems.
Reduces downtime and maintenance costs through early fault detection.
Data Centers:
Ensures uninterrupted operation of data centers by monitoring the insulation of power systems, preventing potential failures and data loss.
Marine and Offshore:
Provides robust insulation monitoring for electrical systems in harsh environments, ensuring safety and reliability on ships and offshore platforms.
Insulation Monitors
Schneider Electric insulation monitors are essential tools for maintaining the safety and reliability of electrical systems across various industries. By offering continuous monitoring, advanced measurement techniques, and integration capabilities, these devices help prevent electrical hazards, reduce downtime, and enhance operational efficiency. Whether in hospitals, industrial facilities, or data centers, Schneider’s insulation monitoring solutions provide peace of mind by ensuring the integrity of electrical insulation.
IMDIFL12C
Specifically built to monitor 12 feeders, whether AC, DC, or AC/DC, within the toroid mounting limit, it supports network voltages ranging from 0 to 1000V AC/DC. The device configuration can be set from the front HMI screen or via the communication port, with settings including alarm thresholds. It clearly indicates which feeder has an insulation fault.
The self-test function initiates automatically every 5 hours and can also be started on demand. If the insulation resistance drops below the predetermined threshold, an alarm is triggered through the IFL output relay and the HMI. Once the fault is resolved, the alarm is cleared and the relay returns to its normal state.
The IMDIFL12C can be powered by a 110V AC to 440V AC or 110V DC to 440V DC source, with a tolerance of plus or minus 15%.
Frequently Asked Questions
What is power monitoring and control?
✅Monitor power levels effectively with power monitors, sensors, and meters. Keep a close watch on vital devices like uninterruptible power supply (UPS) units and power distribution units (PDUs). Ensure seamless monitoring of utility feeds, generators, branch circuits, and other essential infrastructure components.
How does power monitoring work?
✅Power monitoring systems typically comprise a power metering device to gauge overall facility power consumption and assess power quality. Coupled with a monitoring system, these tools track energy distribution within the facility post-metering.
What is power monitoring unit?
✅A Power Monitoring Device plays a crucial role in measuring power consumption, facilitating energy-saving endeavors. While electricity itself remains invisible, it represents a convenient and ubiquitous form of energy that transforms into various manifestations such as heat, light, sound, and power, all of which are extensively utilized.
What is vigilohm?
✅Enhance safety and boost process availability with Vigilohm's range of insulation monitoring devices (IMDs). Designed for IT (ungrounded) networks, these devices offer a straightforward, dependable solution for insulation monitoring, communication, and fault location. Discover how this streamlined offering can elevate both personnel and equipment safety while optimizing process availability.
How does insulation monitor work?
✅Insulation Monitors by DOLD: Insulation Monitoring Made Simple
DOLD's insulation monitors provide seamless insulation monitoring solutions. In the event of an insulation fault, the measuring circuit triggers, allowing a proportional small current to flow. The device's electronics evaluate this current, issuing a notification if the insulation resistance drops below a predefined threshold (response value).
What is an isolation monitor?
✅Explore the Importance of Isolation Monitoring in High-Voltage Vehicle Systems
Isolation monitoring stands as a pivotal safety feature in high-voltage vehicle systems. In modern vehicles, the high-voltage system remains completely isolated from the vehicle chassis. This design safeguards against electrical shock by preventing a single fault in the high-voltage system from posing a risk to individuals.
Değerlendirmeler