Circuit breaker Universal current 220 V DC 230/400 V AC 10kA, 1-pole, C, 50 A
- Stock status:
- In stock
- Manufacturer:
- Siemens
- Product code:
- 5SY5150-7
Main documents
- Product datasheet
- Instruction sheet
- Catalogue
Product | |
Article Number (Market Facing Number) | 5SY5150-7 |
Product Description | Circuit breaker Universal current 220 V DC 230/400 V AC 10kA, 1-pole, C, 50 A |
Product family | Basic Devices |
Product Lifecycle (PLM) | Active Product |
Price data | |
Region Specific PriceGroup / Headquarter Price Group | 12B / 1AC |
List Price | Show prices |
Customer Price | Show prices |
Surcharge for Raw Materials | None |
Metal Factor | L-O—– |
Additional Product Information | |
EAN | 4001869226460 |
UPC | Not available |
Commodity Code | 85362010 |
LKZ_FDB/ CatalogID | LV10.1 |
Product Group | 5505 |
Group Code | P310 |
Country of origin | Germany |
Compliance with the substance restrictions according to RoHS directive | Since: 01.01.2006 |
Product class | B: return restricted, please contact your Siemens partner/contact |
WEEE (2012/19/EU) Take-Back Obligation | Yes |
REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0,1 % (w / w) |
SCIP number | 15088eb2-a3ce-4279-b8fd-d5b2d42466ad |
Product Description
5SY5150-7
The Siemens 5SY5150-7 is a single-pole universal current miniature circuit breaker (MCB) designed to provide dependable overcurrent protection in both AC and DC electrical systems. With a C-characteristic tripping curve and a breaking capacity of 10 kA, it safeguards circuits against overloads and short circuits. Its universal voltage compatibility (220 V DC / 230/400 V AC**) ensures versatile application in residential, commercial, and industrial installations.
Key Features and Specification
- Rated Current (In): 50 A
- Rated Voltage (Un): 220 V DC / 230/400 V AC
- Breaking Capacity: 10 kA
- Poles: 1
- Tripping Curve: C Characteristic (for moderate inrush currents)
- Device Type: Universal Current Miniature Circuit Breaker (MCB)
- Installation: Standard DIN rail mounting
- Country of Origin: Germany
Technical Information
- Number: 5SY5150-7
- EAN: 4001869226460
- Commodity Code: 85362010
- Catalog Reference: LV10.1
- Product Family: Basic Devices
- Product Group: 5505
- Group Code: P310
- Lifecycle Status: Active Product
- Product Class: B – Return restricted (contact Siemens partner)
Applications
- Suitable for residential, commercial, and industrial power distribution
- Protects circuits with moderate inductive or mixed loads, including lighting, motors, and pumps
- Ensures reliable short-circuit and overload protection in AC and DC systems
- Flexible use across universal voltage environments
Summary:
The Siemens 5SY5150-7 MCB is designed for robust circuit protection with a 50 A rated current and 10 kA breaking capacity. Its C-curve tripping characteristic makes it ideal for circuits with moderate inrush currents. With universal voltage capability (220 V DC / 230/400 V AC) and compliance with modern environmental and safety standards, this MCB provides safe, reliable, and flexible protection across a wide range of electrical installations.
Frequently Asked Questions
What is MCB protection?
✅ MCB (Miniature Circuit Breaker) protects against overloads and short circuits. Overload protection works via a bimetallic strip (thermal operation), while short-circuit protection uses a tripping coil (electromagnetic operation). This ensures electrical safety in homes, businesses, and industries.
What is the rule for installing an SPD?
✅ SPD (Surge Protection Device) connections should be as short as possible to minimize the voltage protection level (Up). The total length of connections to the network and earth should not exceed 50 cm to ensure effective surge protection.
How to Set Up a Surge Protector?
1.Turn off power at the circuit breaker.
2. Remove the old outlet.
3. Connect wires to the new surge-protected outlet per the manufacturer’s instructions.
4. Secure the outlet in the box and replace the cover plate.
5. Restore power and test the outlet.
What is the use of RCCB in Siemens?
✅ Siemens Residual Current Circuit Breakers (RCCBs) protect against electric shock by detecting leakage currents. If the leakage exceeds a set limit, the RCCB immediately disconnects the circuit, ensuring safety from direct or indirect contact with live components.
Where is an RCBO used?
✅ RCBOs (Residual Current Circuit Breakers with Overcurrent protection) are commonly used in various residential, commercial, and industrial applications. Typical use cases include power distribution boards, emergency lighting circuits, HVAC (Heating, Ventilation, and Air Conditioning) systems, socket outlets, and swimming pool equipment. RCBOs are ideal for protecting individual circuits where both earth fault and overcurrent protection are required.
Where to Install RCCB?
✅ RCCBs should be installed in the distribution board (DB box) or circuit breaker panel to protect against current leakages caused by faulty wiring, ageing insulation, or defective appliances.