Schneider Electric A9F92302 Miniature Circuit Breaker
Schneider Electric A9F92302 Acti9 iC60L is a 3-pole, 2 A MCB with a sensitive Z-curve tripping characteristic, thermal-magnetic protection, and 15 kA breaking capacity at 400 V AC. Designed for AC/DC applications, it is suitable for selected industrial control, automation, auxiliary, and low-current three-phase circuits.
- Stock status:
- Call for availability
- Manufacturer:
- Product code:
- Schneider Electric A9F92302 Miniature Circuit Breaker
Main documents
- Product datasheet
- Instruction sheet
- Catalogue
Related products
| Specification | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Product Series | Acti9 iC60L |
| Product Code | A9F92302 |
| Product Type | Miniature Circuit Breaker (MCB) |
| Rated Current | 2 A |
| Number of Poles | 3P |
| Protected Poles | 3 |
| Tripping Curve | Z |
| Trip Unit Technology | Thermal-magnetic |
| Rated Voltage | 400 V AC |
| Frequency | 50/60 Hz |
| Network Type | AC/DC |
| Breaking Capacity | 15 kA at 400 V AC according to IEC/EN 60898-1 |
| Ultimate Breaking Capacity | 100 kA at 380–415 V AC according to IEC/EN 60947-2 |
| Ultimate Breaking Capacity at 440 V AC | 70 kA according to IEC/EN 60947-2 |
| DC Breaking Capacity | 20 kA at ≤180 V DC according to IEC/EN 60947-2 |
| Utilisation Category | Category A |
| Isolation Function | Yes |
| Mounting Type | DIN Rail |
| Degree of Protection | IP20 |
| Energy Limitation Class | Class 3 |
| Pollution Degree | 3 |
| Overvoltage Category | IV |
| Compatible Accessories | Auxiliary devices, remote monitoring devices, Vigi residual-current protection devices |
Product Description
Reliable protection is essential in electrical systems where even a minor fault can affect sensitive equipment, interrupt control functions, or create wider operational problems. Miniature circuit breakers are commonly used to isolate affected circuits when abnormal current conditions occur, helping protect conductors and connected equipment from the consequences of overloads and short circuits.
The Schneider Electric A9F92302 is an Acti9 iC60L miniature circuit breaker designed for low-voltage applications requiring a compact three-pole protection device. With a 2 A rated current, Z-curve tripping characteristic, and thermal-magnetic trip technology, it provides a sensitive protection response for circuits where precise overcurrent protection is required.
The three-pole configuration allows the A9F92302 to protect three circuits within a single modular device, making it suitable for selected three-phase control and auxiliary applications. Its 400 V AC rated voltage, 50/60 Hz operating frequency, and compatibility with both AC and DC systems provide additional flexibility when designing electrical panels and control assemblies.
Short-circuit performance is another important characteristic of this model. The A9F92302 provides a 15 kA breaking capacity at 400 V AC according to IEC/EN 60898-1. Under IEC/EN 60947-2, the ultimate breaking capacity reaches 100 kA at 380–415 V AC, while the device can achieve 70 kA at 440 V AC under the specified conditions. This high interruption capability allows the breaker to be considered for installations where prospective fault currents must be carefully evaluated.
The Z-curve characteristic gives the A9F92302 a more sensitive tripping profile than circuit breakers intended for circuits with higher temporary inrush currents. This makes accurate application and coordination particularly important, especially when the breaker is used with electronic equipment, control circuits, automation components, or other sensitive loads.
The compact design of the Acti9 iC60L range also simplifies integration into modular electrical assemblies. DIN-rail mounting allows the breaker to be installed alongside other protection, switching, and monitoring components, while compatible Acti9 accessories can extend the functionality of the installation.
Schneider Electric A9F92302 Technical Specifications
The electrical characteristics of a miniature circuit breaker determine how it behaves during both normal operation and fault conditions. For the A9F92302, the combination of a 2 A rated current, 3-pole configuration, Z-curve tripping, and thermal-magnetic protection defines its intended protection profile.
Breaking capacity must also be considered when evaluating this circuit breaker for an installation. The model provides 15 kA Icn at 400 V AC under IEC/EN 60898-1 and up to 100 kA Icu at 380–415 V AC under IEC/EN 60947-2. These ratings should be compared with the prospective short-circuit current of the installation before the breaker is selected.
Rated Current – 2 A
The 2 A rated current identifies the nominal current level associated with the A9F92302 under its specified operating conditions. This relatively low current rating makes the model relevant to control, auxiliary, automation, and other circuits where higher-rated protection would not provide the required level of circuit coordination.
The breaker rating should always be matched with the conductor capacity, connected load, and overall protection arrangement. Correct coordination helps prevent nuisance tripping during normal operation while maintaining effective protection when abnormal current conditions develop.
Z-Curve Tripping Characteristic
The A9F92302 uses a Z-curve tripping characteristic designed for sensitive circuit protection. Compared with characteristics intended to tolerate greater inrush currents, the Z curve responds at lower instantaneous overcurrent levels.
This characteristic can be useful in circuits containing sensitive electrical or electronic equipment, provided that the expected operating current and transient behavior of the connected load are compatible with the selected breaker.
Three-Pole Configuration
The 3P configuration provides protection across three poles within one compact circuit breaker. This arrangement is particularly useful in three-phase electrical systems where coordinated protection is required without installing separate single-pole devices.
Three protected poles also provide a practical solution for control panels and distribution assemblies where panel space and organized circuit protection are important design considerations.
Breaking Capacity – 15 kA
At 400 V AC and 50/60 Hz, the A9F92302 has a 15 kA Icn breaking capacity according to IEC/EN 60898-1. This represents the short-circuit current level that the device is designed to interrupt under the conditions defined by the applicable standard.
Under IEC/EN 60947-2, the model provides an Icu of up to 100 kA at 380–415 V AC and 70 kA at 440 V AC. The applicable breaking capacity must always be evaluated according to the actual operating voltage and installation conditions.
Thermal-Magnetic Protection
The A9F92302 uses a thermal-magnetic trip unit to address both sustained overloads and high fault currents. The thermal mechanism responds to prolonged overcurrent conditions, while the magnetic mechanism provides rapid operation when a significant short-circuit current occurs.
This combination gives the breaker two complementary protection mechanisms within a single compact device.
AC and DC Compatibility
The A9F92302 is designed for use in AC and DC networks, with the applicable interruption ratings depending on the voltage and circuit configuration. This capability makes the device suitable for a range of low-voltage protection applications where the electrical characteristics fall within its specified ratings.
Features and Benefits of the Schneider Electric A9F92302
The A9F92302 combines sensitive circuit protection with a compact three-pole construction. Its 2 A rated current, Z-curve characteristic, and thermal-magnetic trip technology provide a defined protection profile for low-current circuits.
Its high short-circuit interruption capability is another important advantage. With a 15 kA Icn at 400 V AC and an Icu of up to 100 kA at 380–415 V AC, the breaker can be considered for installations where the available fault current requires a protection device with substantial interruption capability.
DIN-rail mounting makes installation straightforward in modular electrical panels, while the Acti9 iC60L platform allows the breaker to be combined with compatible auxiliary, monitoring, and residual-current protection devices.
Key Benefits
The Schneider Electric A9F92302 provides sensitive Z-curve protection for low-current circuits while maintaining three-pole circuit protection in a compact modular format. Its thermal-magnetic protection technology addresses both overload and short-circuit conditions, while its high breaking capacity provides additional protection capability in installations with significant prospective fault currents.
The device also offers AC/DC compatibility, DIN-rail mounting, and integration with the wider Acti9 accessory ecosystem, giving panel designers additional flexibility when configuring electrical protection systems.
Applications of the Schneider Electric A9F92302 Miniature Circuit Breaker
The A9F92302 is intended for applications where a low rated current, three-pole configuration, and sensitive Z-curve protection are required. Its electrical characteristics make it relevant to selected control, automation, auxiliary, and low-current three-phase circuits.
Industrial Control Circuits
Industrial control systems often contain low-current circuits that require independent protection from larger power circuits. The A9F92302 can provide dedicated protection where a 2 A rating and Z-curve response correspond to the requirements of the control system.
Electrical Distribution Panels
The three-pole configuration allows the breaker to be incorporated into suitable three-phase distribution arrangements. DIN-rail mounting also enables efficient integration into modular distribution boards and control cabinets.
Industrial Automation Systems
Automation installations contain numerous control and auxiliary circuits that require reliable protection against abnormal current conditions. The A9F92302 can be used in suitable circuits where its 2 A rating and sensitive Z-curve characteristic match the equipment requirements.
Machine Control Panels
Machine control panels frequently combine sensitive control components with larger electrical loads. Dedicated low-current circuit protection can help isolate faults within individual control circuits without unnecessarily affecting unrelated parts of the machine.
Auxiliary Circuits
Auxiliary circuits used within industrial electrical systems can require independent overcurrent protection. The A9F92302 provides three-pole protection for suitable auxiliary applications where the circuit’s current and voltage characteristics fall within the device’s ratings.
Sensitive Electrical Circuits
Electronic and sensitive electrical equipment can require a more responsive protection characteristic than standard circuit breakers provide. The Z-curve design of the A9F92302 can be appropriate for selected applications where sensitive overcurrent protection is required.
Why Buy the Schneider Electric A9F92302?
The Schneider Electric A9F92302 provides a specific combination of 3 poles, 2 A rated current, Z-curve tripping, thermal-magnetic protection, and high short-circuit interruption capability. These characteristics make accurate product selection important when specifying a circuit breaker for a particular installation.
The Acti9 iC60L platform also supports a range of additional functions through compatible accessories. This allows the circuit breaker to be incorporated into protection systems that require auxiliary signaling, remote monitoring, or additional residual-current protection.
Advantages of Choosing the Right Model
Correct circuit breaker selection helps ensure that the protection device corresponds to the electrical load, conductor capacity, prospective fault current, and system configuration. For circuits requiring three-pole protection with a 2 A rating and Z-curve response, the A9F92302 provides a clearly defined electrical profile.
Its compact construction, high interruption capability, DIN-rail installation, and compatibility with Acti9 accessories make it suitable for professional electrical panel applications where reliable and precisely matched circuit protection is required.
Buy the Schneider Electric A9F92302 from GeeTech
Reliable sourcing is an important consideration when purchasing industrial electrical equipment, particularly when the exact manufacturer reference determines the electrical characteristics of the protection device.
The Schneider Electric A9F92302 can be sourced through GeeTech for industrial installations, engineering projects, replacement requirements, control-panel assembly, and electrical procurement applications.
Why Purchase from GeeTech?
GeeTech supports international customers requiring Schneider Electric equipment with product sourcing, quotation assistance, technical support, and worldwide shipping. Both individual replacement requirements and larger industrial procurement projects can be supported according to product availability and order requirements.
Schneider Electric A9F92302 Price
The final price of the Schneider Electric A9F92302 depends on factors including current stock availability, order quantity, market conditions, logistics costs, and currency exchange rates.
GeeTech provides quotations according to current purchasing requirements, allowing customers to obtain updated pricing and availability information before placing an order.
Frequently Asked Questions About the Schneider Electric A9F92302
The Schneider Electric A9F92302 is a 3-pole Acti9 iC60L miniature circuit breaker with a 2 A rated current, Z-curve tripping characteristic, and thermal-magnetic protection. It is designed for suitable low-voltage AC and DC circuit protection applications.
What is the rated current of the Schneider Electric A9F92302?
The A9F92302 has a 2 A rated current. The selection of this rating should take into account the connected load, conductor capacity, and protection requirements of the electrical system.
How many poles does the A9F92302 have?
The A9F92302 is a 3-pole circuit breaker, with all three poles protected.
What is the tripping curve of the A9F92302?
The A9F92302 uses a Z-curve tripping characteristic, providing a sensitive response to overcurrent conditions.
What is the breaking capacity of the A9F92302?
The A9F92302 provides a 15 kA breaking capacity at 400 V AC according to IEC/EN 60898-1. Under IEC/EN 60947-2, its ultimate breaking capacity reaches 100 kA at 380–415 V AC and 70 kA at 440 V AC under the specified conditions.
Does the A9F92302 support AC and DC applications?
Yes. The A9F92302 is designed for AC and DC networks, although the applicable breaking capacity varies according to the operating voltage and circuit conditions.
What type of protection does the A9F92302 use?
The circuit breaker uses thermal-magnetic protection technology, combining thermal protection for overload conditions with magnetic protection for short-circuit events.
Can the A9F92302 be installed on a DIN rail?
Yes. The A9F92302 is designed for DIN-rail mounting, allowing it to be integrated into modular electrical panels and control cabinets.
Is the Schneider Electric A9F92302 suitable for industrial applications?
The A9F92302 can be used in suitable industrial control, automation, auxiliary, and low-current three-phase applications where its 2 A rating, 3P configuration, and Z-curve characteristic match the requirements of the electrical system.
Can the A9F92302 be used with additional accessories?
The Acti9 iC60L range supports compatible auxiliary devices, remote monitoring solutions, and Vigi residual-current protection accessories, allowing additional functionality to be incorporated into suitable electrical installations.
Can GeeTech ship the Schneider Electric A9F92302 internationally?
GeeTech provides international sourcing and worldwide shipping services for industrial electrical equipment. Current availability, pricing, and delivery conditions can be confirmed according to the required quantity and destination.
Conclusion: Why Choose the Schneider Electric A9F92302?
The Schneider Electric A9F92302 Miniature Circuit Breaker combines a 3-pole configuration, 2 A rated current, Z-curve tripping characteristic, and thermal-magnetic protection in the Acti9 iC60L platform. Its 15 kA breaking capacity at 400 V AC under IEC/EN 60898-1 and up to 100 kA ultimate breaking capacity at 380–415 V AC under IEC/EN 60947-2 provide substantial fault-interruption capability for suitable low-voltage applications.
Its sensitive protection profile, AC/DC compatibility, DIN-rail mounting, and compatibility with additional Acti9 accessories make the A9F92302 a practical option for selected industrial control, automation, auxiliary, and three-phase low-current circuits.
Accurate selection of the circuit breaker remains essential for achieving proper coordination between the protective device, conductors, connected equipment, and fault conditions. The Schneider Electric A9F92302 provides a clearly defined set of electrical characteristics for applications requiring this specific protection configuration.


















Reviews
There are no reviews yet.