Product Catalogue

Download Product Catalogue

100% Genuine Products

Supplier of industrial electrical products

1 year warranty

The products have a warranty

Main
RangePowerLogic
Product namePowerLogic PM5000
Device short namePM5760
product or component typePower meter
Complementary
Power quality analysisUp to the 63rd harmonic
waveform capture
voltage sag and swell detection
residual current monitoring
Metering typeMeasured neutral current
Calculated ground current
Residual current I0
Device applicationGateway
WAGES metering
Power monitoring
Multi-tariff
Type of measurementCurrent
Voltage
Frequency
Power factor
Energy
Active and reactive power
supply voltage100…300 V DC
90…528 V AC 45…65 Hz
Network frequency60 Hz
50 Hz
[In] rated current1 A
5 A
type of network3P + N
3P
1P + N
Maximum power consumption in VA16 VA at 480 V
Ride-through time35 ms 120 V AC typical
129 ms 230 V AC typical
50 ms 125 V DC typical
Display typeMonochrome graphic LCD
display resolution128 x 128 pixels
Sampling rate128 samples/cycle
Measurement current50…10000 mA
Analogue input typeVoltage (impedance 5 MOhm)
Current (impedance <= 0.3 mOhm)
Measurement voltage20…400 V AC 45…65 Hz between phase and neutral
20…828 V AC 45…65 Hz between phases
Frequency measurement range45…65 Hz
Number of inputs4 digital
Measurement accuracyApparent power +/- 0.5 %
Frequency +/- 0.05 %
Active energy +/- 0.2 %
Reactive energy +/- 1 %
Active power +/- 0.2 %
Voltage +/- 0.1 %
Power factor +/- 0.005
Current +/- 0.15 %
Reactive power +/- 1 %
Accuracy classClass 0.2S active energy conforming to IEC 62053-22
Number of outputs2 digital
Information displayedTariff (8)
Communication port protocolModbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none – 2 wires, insulation 2500 V
JBUS
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V
Ethernet Modbus TCP/IP daisy chain
BACnet IP
DNP3 over ethernet
Communication port supportRS485
ETHERNET
Communication gatewayEthernet/serial
Data recordingEvent logs
Maintenance logs
Min/max of instantaneous values
Data logs
Alarm logs
Time stamping
Memory capacity1.1 MB
Web servicesAlarm notification by e-mail
Web server
Diagnostic via predefined web pages
Real time viewing of data
Ethernet serviceSNTP client
SNMP-Traps
Connections – terminalsVoltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
RS485 link: screw terminal block4
Digital input: screw terminal block8
Digital output: screw terminal block4
Ethernet network: RJ45 connector2
mounting modeFlush-mounted
Mounting supportFramework
StandardsEN 50470-3
IEC 61557-12:2015
IEC 62053-22:2020
IEC 62053-24
IEC 60529
EN 50470-1
UL 61010-1
IEC 62053-23:2020
IEC 62052-11:2020
IEC 62052-31:2015
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
Width96 mm
Depth72 mm
Height96 mm
net weight450 g
Environment
Electromagnetic compatibilityLimits for harmonic current emissions class A conforming to IEC 61000-3-2
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
Electrostatic discharge – test level: 8 kV level 4 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Surge immunity test level 4 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
IP degree of protectionIP54 display: conforming to IEC 60529
IP30 rear: conforming to IEC 60529
Relative humidity5…95 % at 50 °C non-condensing
Pollution degree2
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-40…85 °C
Operating altitude<= 3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12.0 cm
Package 1 Width12.5 cm
Package 1 Length12.5 cm
Package 1 Weight647.0 g
Unit Type of Package 2S03
Number of Units in Package 212
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight8.152 kg
Unit Type of Package 3P06
Number of Units in Package 396
Package 3 Height75 cm
Package 3 Width80 cm
Package 3 Length60 cm
Package 3 Weight73.216 kg

Product Description

Schneider Power Meters

Frequently Asked Questions

✅ Energy monitoring is the process of tracking and analyzing energy consumption in a building or facility. It helps identify patterns, inefficiencies, and opportunities to reduce energy costs. With the right tools, such as PowerLogic meters, users gain detailed insights into how, where, and when energy is being used.

Yes, power meters are a worthwhile investment for homes, commercial buildings, and industrial facilities. By monitoring energy usage, they help detect waste, improve energy efficiency, and lower electricity bills. For businesses, they also support sustainability goals and compliance with energy standards.

Power meters work by continuously measuring voltage and current, then calculating power (watts) and energy usage (kilowatt-hours). They provide detailed real-time data, and some models offer logging, alarms, and remote communication features for integration with building or energy management systems.

Schneider Electric’s PowerLogic meters offer high accuracy, scalability, and advanced features such as power quality analysis, data logging, and seamless integration with EcoStruxure™ software. They are ideal for energy monitoring, cost allocation, and preventive maintenance in critical energy applications.

Reviews

There are no reviews yet.

Be the first to review “METSEPM5760”

Your email address will not be published. Required fields are marked *