| Range | Vigilohm |
|---|---|
| Device short name | IM9 |
| product or component type | Insulation monitoring device |
| Device application | Marine application Standard environment application |
| electrical circuit type | Small and not disturbed network |
| Earthing system | IT |
| Network rated voltage | 0…600 V – AC at 45…440 Hz (device connected to neutral) 0…480 V – AC at 45…440 Hz (device connected to phase) |
|---|---|
| Type of measurement | Network insulation resistance |
| Threshold setting | Pre-alarm: 2…500 kOhm Alarm: 1…250 kOhm |
| Response time | <= 7 s |
| auxiliary supply voltage | 110…415 V AC 45…440 Hz +/- 15 % 125…250 V DC +/- 15 % |
| Power consumption in VA | 7 VA |
| Measurement current | 0…70 µA |
| internal impedance | 230 kOhm – AC at 45…440 Hz |
| Test function | Remote test Local |
| output contact | 1 C/O standard or fail-safe |
| breaking capacity | 250 V – AC at 6 A 12…24 V – DC at 6 A |
| Communication port protocol | – |
| Mounting mode | Clip-on Flush-mounted |
| Mounting support | DIN rail Panel |
| Mounting position | Horizontal Vertical |
| Connections – terminals | Tunnel type terminals0.2…2.5 mm² |
| Material | Thermoplastic |
| net weight | 0.2 kg |
| Height | 90 mm |
| Width | 71 mm |
| Depth | 67.5 mm |
| IP degree of protection | Case: IP20 Front face: IP40 |
|---|---|
| Environmental characteristic | Exposure to damp heat not in service conforming to IEC 60068-2-30 Exposure to damp heat in service conforming to IEC 60068-2-56 Salt mist conforming to IEC 60068-2-52 |
| Type of installation | Indoor |
| Standards | IEC 61557-8 IEC 60664-1 |
| Product certifications | EAC CE BV RMRS DNV |
| Ambient air temperature for operation | -25…55 °C |
| ambient air temperature for storage | -40…70 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.000 cm |
| Package 1 Width | 8.400 cm |
| Package 1 Length | 9.600 cm |
| Package 1 Weight | 230.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 36 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.489 kg |
Product Description
IMD-IM9

Key Features:
- Range: Vigilohm
- Device Type: Insulation Monitoring Device (IMD)
- Voltage Range: 110-415VCA
- Application: Pure AC systems of limited size with low disturbances
Functionality:
The Vigilohm IM9 is engineered to monitor the insulation resistance of pure AC systems by injecting a DC current between the network and ground. This device is essential for maintaining the safety and reliability of electrical networks, as recommended by standards.
Configuration:
Settings: Adjustable alarm and pre-alarm thresholds available on the front of the device.
Manual Auto-Test: Ensures the device is functioning correctly.
Operation:
If the system’s insulation resistance falls below the configured threshold, indicating a ground fault, an alarm is triggered through the IMD output relay. Once the fault is resolved, the alarm is cleared, and the relay returns to its normal state.
Installation:
Mounting: DIN rail compatible
Summary
The Vigilohm IMD-IM9 is a reliable solution for monitoring insulation resistance in pure AC systems, ensuring system safety and compliance with industry standards.
Frequently Asked Questions
What is power monitoring and control?
✅Monitor power levels effectively with power monitors, sensors, and meters. Keep a close watch on vital devices like uninterruptible power supply (UPS) units and power distribution units (PDUs). Ensure seamless monitoring of utility feeds, generators, branch circuits, and other essential infrastructure components.
How does power monitoring work?
✅Power monitoring systems typically comprise a power metering device to gauge overall facility power consumption and assess power quality. Coupled with a monitoring system, these tools track energy distribution within the facility post-metering.
What is power monitoring unit?
✅A Power Monitoring Device plays a crucial role in measuring power consumption, facilitating energy-saving endeavors. While electricity itself remains invisible, it represents a convenient and ubiquitous form of energy that transforms into various manifestations such as heat, light, sound, and power, all of which are extensively utilized.
What is vigilohm?
✅Enhance safety and boost process availability with Vigilohm's range of insulation monitoring devices (IMDs). Designed for IT (ungrounded) networks, these devices offer a straightforward, dependable solution for insulation monitoring, communication, and fault location. Discover how this streamlined offering can elevate both personnel and equipment safety while optimizing process availability.
How does insulation monitor work?
✅Insulation Monitors by DOLD: Insulation Monitoring Made Simple
DOLD's insulation monitors provide seamless insulation monitoring solutions. In the event of an insulation fault, the measuring circuit triggers, allowing a proportional small current to flow. The device's electronics evaluate this current, issuing a notification if the insulation resistance drops below a predefined threshold (response value).
What is an isolation monitor?
✅Explore the Importance of Isolation Monitoring in High-Voltage Vehicle Systems
Isolation monitoring stands as a pivotal safety feature in high-voltage vehicle systems. In modern vehicles, the high-voltage system remains completely isolated from the vehicle chassis. This design safeguards against electrical shock by preventing a single fault in the high-voltage system from posing a risk to individuals.

















Reviews
There are no reviews yet.