| Range | Vigilohm |
|---|---|
| Device short name | IM400 |
| product or component type | Insulation monitoring device |
| Device application | Marine application Standard environment application |
| electrical circuit type | Large or highly disturbed network |
| Earthing system | IT |
| User language | Italian French German Chinese Portuguese Russian Spanish English |
| Network rated voltage | 0…480 V – AC at 45…440 Hz (device connected to phase) 0…830 V – AC at 45…440 Hz (device connected to neutral) 0…480 V – DC |
|---|---|
| Type of measurement | Network insulation resistance – measurement range: 10 Ohm…10 MOhm Earth leakage capacitance – measurement range: 0.1…500 µF |
| Local signalling | Green indicator light: satisfactory insulation resistance White indicator light: below prevention threshold Red indicator light: wiring or internal fault Yellow indicator light: insulation fault Yellow flashing indicator light: communication |
| Threshold setting | Pre-alarm: 1 kOhm…1 MOhm Alarm: 40 Ohm…500 kOhm |
| Time delay range | 0…120 min for signalling circuit |
| Response time | <= 4 s |
| auxiliary supply voltage | 100…440 V AC 50/60 Hz +/- 15 % 100…440 V AC 400 Hz +/- 15 % 100…440 V DC +/- 15 % |
| Power consumption in VA | 25 VA |
| Measurement voltage | 120 V 15 V 33 V |
| Measurement current | 0…3 mA 0…825 µA 0…375 µA |
| internal impedance | 40 kOhm – AC at 0.1…440 Hz 40 kOhm – DC |
| Test function | Manual Self test |
| output contact | 2 C/O standard or fail-safe |
| breaking capacity | 250 V – AC at 6 A 48 V – DC at 1 A |
| Input function | Injection inhibition: 24 V AC 5 mA |
| Communication port protocol | Modbus |
| Communication port support | RS485 |
| Display type | Digital display |
| Mounting mode | Flush-mounted |
| Mounting support | Panel |
| Mounting position | Horizontal |
| Connections – terminals | Removable screw terminal block0.2…2.5 mm² |
| Material | Thermoplastic |
| Overvoltage category | III |
| net weight | 0.75 kg |
| Cut-out dimensions | 112 x 148 mm |
| Height | 123 mm |
| Width | 159 mm |
| Depth | 90 mm |
| Dielectric strength | 4000 V – AC 5500 V – DC |
|---|---|
| IP degree of protection | Case: IP20 Front face: IP54 |
| Environmental characteristic | Exposure to damp heat not in service conforming to IEC 60068-2-30 Exposure to damp heat in service conforming to IEC 60068-2-56 Salt mist conforming to IEC 60068-2-52 |
| Operating altitude | <= 3000 m |
| Pollution degree | 2 |
| Relative humidity | 0…90 % |
| Type of installation | Indoor |
| Standards | IEC 60364-4-41 IEC 61010-1 IEC 61557-8 CSA C22.2 No 14-05 IEC 60364-5-51 UL 508 |
| Product certifications | DNV RMRS CE ABS EAC CSA cULus UL |
| Ambient air temperature for operation | -25…55 °C |
| ambient air temperature for storage | -40…70 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.000 cm |
| Package 1 Width | 17.500 cm |
| Package 1 Length | 21.200 cm |
| Package 1 Weight | 946.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.458 kg |
Product Description
IMD-IM400

Key Features and Functionality:
1. Purpose:
Monitors the insulation resistance of ungrounded (IT) electrical networks.
Measures system insulation by injecting a low-frequency AC current between the network and ground.
2. Compatibility:
Suitable for large and disturbed AC, DC, and ACDC systems.
Can monitor networks up to 830V AC when connected to neutral, 480V AC when connected to line, and 480V DC, with capacitance up to 500 microfarads.
3. Measurement Capabilities:
Insulation resistance: From 10 ohms to 10 megohms.
Capacitance and temporary faults can also be displayed.
4. Configuration and Settings:
Settings can be configured on the front of the device via the HMI screen or through the communication port.
Configurable parameters include network type, alarm and pre-alarm thresholds, alarm delay (from 0 to 7200 seconds), and more.
5. Display and Alarms:
The black and white screen shows insulation resistance, capacitance, and temporary faults.
Auto-test initiates every 5 hours automatically, or on demand.
An alarm is triggered through the IMD output relay if insulation resistance drops below the set threshold, indicating a ground fault.
The alarm clears automatically once the fault is resolved, and the alarm relay returns to normal.
6. Power Supply:
Can be supplied by a 110VAC to 440VAC source or a 110VDC to 440VDC source, with a tolerance of ±15%.
7. Installation and Protection:
Designed for flush mounting, such as on an enclosure door.
Front face ingress protection: IP5.
Rear ingress protection: IP20.
Overvoltage category III with a rating of 300V.
8. Communication:
Equipped with an RS485 communication port supporting the Modbus protocol.
Summary
The IMD-IM400 is recommended for monitoring large and disturbed electrical systems in industrial environments, where maintaining electrical integrity is critical. By continuously monitoring insulation resistance and providing timely alarms for ground faults, it ensures the safety and reliability of electrical networks, helping to prevent potential hazards and system failures.
Frequently Asked Questions
What is power monitoring and control?
✅Monitor power levels effectively with power monitors, sensors, and meters. Keep a close watch on vital devices like uninterruptible power supply (UPS) units and power distribution units (PDUs). Ensure seamless monitoring of utility feeds, generators, branch circuits, and other essential infrastructure components.
How does power monitoring work?
✅Power monitoring systems typically comprise a power metering device to gauge overall facility power consumption and assess power quality. Coupled with a monitoring system, these tools track energy distribution within the facility post-metering.
What is power monitoring unit?
✅A Power Monitoring Device plays a crucial role in measuring power consumption, facilitating energy-saving endeavors. While electricity itself remains invisible, it represents a convenient and ubiquitous form of energy that transforms into various manifestations such as heat, light, sound, and power, all of which are extensively utilized.
What is vigilohm?
✅Enhance safety and boost process availability with Vigilohm's range of insulation monitoring devices (IMDs). Designed for IT (ungrounded) networks, these devices offer a straightforward, dependable solution for insulation monitoring, communication, and fault location. Discover how this streamlined offering can elevate both personnel and equipment safety while optimizing process availability.
How does insulation monitor work?
✅Insulation Monitors by DOLD: Insulation Monitoring Made Simple
DOLD's insulation monitors provide seamless insulation monitoring solutions. In the event of an insulation fault, the measuring circuit triggers, allowing a proportional small current to flow. The device's electronics evaluate this current, issuing a notification if the insulation resistance drops below a predefined threshold (response value).
What is an isolation monitor?
✅Explore the Importance of Isolation Monitoring in High-Voltage Vehicle Systems
Isolation monitoring stands as a pivotal safety feature in high-voltage vehicle systems. In modern vehicles, the high-voltage system remains completely isolated from the vehicle chassis. This design safeguards against electrical shock by preventing a single fault in the high-voltage system from posing a risk to individuals.

















Reviews
There are no reviews yet.