ATV12H018M2
variable speed drive, Altivar 12, 0.18kW, 0.25hp, 200 to 240V, 1 phase
- Stock status:
- In stock
- Manufacturer:
- Schneider
- Product code:
- ATV12H018M2
Main documents
Range of Product | Altivar 12 |
---|---|
Product or Component Type | Variable speed drive |
Product Specific Application | Simple machine |
Mounting Mode | Cabinet mount |
Communication Port Protocol | Modbus |
Supply frequency | 50/60 Hz +/- 5 % |
[Us] rated supply voltage | 200…240 V – 15…10 % |
Nominal output current | 1.4 A |
Maximum Horse Power Rating | 0.25 hp |
Motor power kW | 0.18 kW |
Maximum Horse Power Rating | 0.25 hp |
EMC filter | Integrated |
IP degree of protection | IP20 |
Discrete input number | 4 |
---|---|
Discrete output number | 2 |
Analogue input number | 1 |
Analogue output number | 1 |
Relay output number | 1 |
Physical interface | 2-wire RS 485 |
Connector Type | 1 RJ45 |
Continuous output current | 1.4 A 4 kHz |
Method of access | Server Modbus serial |
Speed drive output frequency | 0.5…400 Hz |
Speed range | 1…20 |
Sampling duration | 20 ms +/- 1 ms logic input 10 ms analogue input |
Linearity error | +/- 0.3 % of maximum value analogue input |
Frequency resolution | Analog input converter A/D, 10 bits Display unit 0.1 Hz |
Time constant | 20 ms +/- 1 ms for reference change |
Transmission Rate | 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity |
Communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
Type of polarization | No impedance |
4 quadrant operation possible | False |
Asynchronous motor control profile | Voltage/frequency ratio (V/f) Sensorless flux vector control Quadratic voltage/frequency ratio |
Maximum output frequency | 4 kHz |
Transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor |
Acceleration and deceleration ramps | U Linear from 0 to 999.9 s S |
Motor slip compensation | Preset in factory Adjustable |
Switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor |
Nominal switching frequency | 4 kHz |
Braking to standstill | By DC injection |
Brake chopper integrated | False |
Line current | 3.4 A 100 V heavy duty) 2.8 A 120 V heavy duty) |
Maximum Input Current per Phase | 2.8 A |
Maximum output voltage | 240 V |
Apparent power | 0.7 kVA 240 V heavy duty) |
Maximum transient current | 2.1 A 60 s heavy duty) 2.3 A 2 s heavy duty) |
Network Frequency | 50-60 Hz |
Relative symmetric network frequency tolerance | 5 % |
Prospective line Isc | 1 kA |
Base load current at high overload | 1.4 A |
Power dissipation in W | Natural 18.0 W |
With safety function Safely Limited Speed (SLS) | False |
With safety function Safe brake management (SBC/SBT) | False |
With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | False |
With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | False |
With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False |
Protection type | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Tightening torque | 7.08 lbf.in (0.8 N.m) |
Insulation | Electrical between power and control |
Quantity per Set | Set of 1 |
Width | 2.83 in (72 mm) |
Height | 5.63 in (143 mm) |
Depth | 4.02 in (102.2 mm) |
Net Weight | 1.54 lb(US) (0.7 kg) |
Operating altitude | > 3280.84…6561.68 ft (> 1000…2000 m) with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating |
---|---|
Operating position | Vertical +/- 10 degree |
Product Certifications | NOM CSA C-tick UL GOST RCM KC |
marking | CE |
Standards | UL 508C UL 618000-5-1 IEC 61800-5-1 IEC 61800-3 |
Assembly style | On base plate |
Electromagnetic compatibility | Electrical fast transient/burst immunity test level 4 IEC 61000-4-4 Electrostatic discharge immunity test level 3 IEC 61000-4-2 Immunity to conducted disturbances level 3 IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 Surge immunity test level 3 IEC 61000-4-5 Voltage dips and interruptions immunity test IEC 61000-4-11 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
Overvoltage category | Class III |
Regulation loop | Adjustable PID regulator |
Electromagnetic emission | Radiated emissions environment 1 category C2 IEC 61800-3 2…16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 IEC 61800-3 2…12 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 IEC 61800-3 2, 4 and 16 kHz shielded motor cable <32.81 ft (10 m) Conducted emissions with additional EMC filter environment 1 category C1 IEC 61800-3 4…12 kHz shielded motor cable <65.62 ft (20 m) Conducted emissions with additional EMC filter environment 1 category C2 IEC 61800-3 4…12 kHz shielded motor cable <164.04 ft (50 m) Conducted emissions with additional EMC filter environment 2 category C3 IEC 61800-3 4…12 kHz shielded motor cable <164.04 ft (50 m) |
Vibration resistance | 1 gn 13…200 Hz)IEC 60068-2-6 1.5 mm peak to peak 3…13 Hz) – drive unmounted on symmetrical DIN rail – IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation IEC 60068-2-3 5…95 % without dripping water IEC 60068-2-3 |
Noise level | 0 dB |
Pollution degree | 2 |
Ambient air transport temperature | -13…158 °F (-25…70 °C) |
Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating 104…140 °F (40…60 °C) with current derating 2.2 % per °C |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Category | US1CP4B22042 |
---|---|
Discount Schedule | CP4B |
GTIN | 3606480071089 |
Returnability | Yes |
Country of origin | ID |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 4.72 in (12.000 cm) |
Package 1 Width | 7.32 in (18.600 cm) |
Package 1 Length | 7.68 in (19.500 cm) |
Package 1 Weight | 31.57 oz (895.000 g) |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 45 |
Package 2 Height | 29.53 in (75.000 cm) |
Package 2 Width | 23.62 in (60.000 cm) |
Package 2 Length | 31.50 in (80.000 cm) |
Package 2 Weight | 116.36 lb(US) (52.780 kg) |
Product Description
Schneider Electric
Schneider Electric is a multinational corporation specializing in energy management and automation solutions. With operations in over 100 countries, the company offers a wide range of products and services for various industries, including residential, commercial, and industrial.
Schneider Electric is focused on sustainability and innovation, aiming to help their customers manage energy efficiently and reduce their environmental impact.
Schneider Driver
Looking for reliable driver solutions for your Schneider Electric devices? Schneider Electric offers a range of drivers to ensure seamless integration and optimal performance of your automation and control systems. Whether you need drivers for industrial automation, energy management, or building automation, Schneider Electric provides robust and efficient drivers to meet your requirements.
Schneider Soft Starter
Schneider Electric offers a comprehensive range of soft starters designed to provide smooth and efficient motor starting and stopping. Soft starters are essential for reducing mechanical stress on motors and minimizing electrical surges, making them ideal for various industrial applications.
Altistart 12
The Schneider Electric Altistart 12 is a compact and efficient soft starter designed for the smooth control of 3-phase asynchronous motors. It is tailored to meet the needs of various simple and complex applications, ensuring reliable motor starting and stopping with reduced mechanical stress and enhanced operational efficiency.
Key Features of Altistart 12:
Motor Control:
- Provides smooth starting and stopping of motors, minimizing mechanical stress and extending the service life of equipment.
Compact Design:
- Space-saving design allows for easy integration into existing control panels and equipment.
Power Range:
- Supports a wide range of motor power ratings, making it suitable for various industrial applications.
Built-in Protections:
- Includes protections against overloads, short circuits, and phase imbalances, ensuring safe and reliable motor operation.
Ease of Use:
- Simple to install and configure, with user-friendly settings and interface.
ATV12H018M2
The Altivar 12 (ATV12H018M2) from Schneider Electric is a versatile variable speed drive specifically designed for commercial equipment and simple machinery. Below is a detailed overview of its features and specifications:
Key Features and Specifications:
Power and Voltage:
- Rated Power: Up to 0.18kW (0.25hp)
- Voltage Range: 200V to 240V AC, single-phase
Design and Cooling:
- The drive is designed with a heatsink, suitable for normal environments.
- Fan-cooled enclosure ensures effective heat dissipation.
Functionality:
- Equipped with advanced PID (Proportional, Integral, Derivative) control for precise process regulation.
- “Catch on the fly” function allows for smooth motor restart without stopping the machine.
Ease of Use:
- Basic cabling and simple motor control settings facilitate easy installation and operation.
- Can be delivered with or without a heatsink, with an embedded EMC filter, or as a standard version, depending on specific needs.
Communication:
- Integrates Modbus communication protocol as a standard feature, ensuring compatibility with various control systems.
Applications:
- Ideal for simple industrial applications, commercial machines, and HVAC systems.
- Commonly used with conveyors, pumps, extractors, access barriers, and treadmills.
Compliance:
- Conforms to international standards including IEC and UL, ensuring safety and reliability in diverse environments.
Energy Efficiency:
- Optimized for power and torque application, particularly in ventilation and pumping applications, allowing for up to 30% energy savings.
Software Compatibility:
- Compatible with SoMove software, which allows for saving and transferring configurations to spare drives, reducing maintenance downtime and ensuring quick replacements.
The Schneider Electric Altivar 12 (ATV12H018M2) variable speed drive offers a reliable, efficient, and versatile solution for managing motor speeds in various simple applications. Its ease of installation, advanced functionality, and energy-saving features make it an excellent choice for enhancing operational efficiency and reducing energy costs.
Frequently Asked Questions
What is a Schneider Soft Starter?
✅ A soft starter is a solid-state device designed to protect AC electric motors from damage caused by sudden power surges. By limiting the large initial inrush of current during motor startup, soft starters ensure a smoother and safer operation, thereby extending the lifespan of the motor.
How Does a Soft Starter Work?
✅ A soft starter continuously controls the motor's voltage supply during the start-up phase. By adjusting the motor to the machine's load behavior, it ensures that mechanical operating equipment accelerates smoothly. This gradual acceleration lengthens the service life of the equipment, improves operating behavior, and smooths workflows, leading to more efficient and reliable operations.
what is a Schneider Drive
✅ A Schneider Electric drive, often referred to as a variable frequency drive (VFD) or variable speed drive (VSD), is an advanced device used to control the speed and torque of electric motors. These drives are integral components in modern industrial automation, providing precise motor control, energy efficiency, and enhanced operational performance.
What is the Difference Between VFD and Soft Starter?
✅ The primary difference between a Variable Frequency Drive (VFD) and a soft starter is their functionality. A VFD can vary the speed of a motor, providing precise control over its operation, while a soft starter only controls the starting and stopping phases of the motor. When considering an application, soft starters are typically more cost-effective and compact. However, if speed control is required, a VFD is the better choice.
Which is Better, VFD or Soft Starter?
✅ The primary difference between a Variable Frequency Drive (VFD) and a soft starter is their functionality. A VFD can vary the speed of a motor, providing precise control over its operation, while a soft starter only controls the starting and stopping phases of the motor. When considering an application, soft starters are typically more cost-effective and compact. However, if speed control is required, a VFD is the better choice.
Can a VFD Replace a Soft Starter?
✅Essentially, a Variable Frequency Drive (VFD) functions as a soft starter with added speed control capabilities. If your application requires speed variation, a VFD is the ideal choice. However, if you only need to control the inrush of current during startup and prefer a smaller, more cost-effective device, a soft starter is the better option.
Reviews
There are no reviews yet.