ATS01N212LU

5/5 - (5 votes)

soft starter for asynchronous motor, Altistart 01, ATS01, 12A, 200 to 240V, 2.2 to 3kW

Main documents

Main
Range of ProductAltistart 01
Product or Component TypeSoft starter
product destinationAsynchronous motors
Product Specific ApplicationSimple machine
Device short nameATS01
Phase3 phase
[Us] rated supply voltage200…240 V – 10…10 %
Motor power kW3 kW, 3 phase 200…240 V
2.2 kW, 3 phase 200…240 V
Maximum Horse Power Rating3 hp, 3 phase 200…240 V
IcL starter rating12 A
Utilisation categoryAC-53B EN/IEC 60947-4-2
Current consumption60 A at nominal load
Type of startStart with voltage ramp
Power dissipation in W4 W at full load and at end of starting
124 W in transient state
Complementary
Assembly styleWith heat sink
Function AvailableIntegrated bypass
Supply voltage limits180…264 V
Supply frequency50…60 Hz – 5…5 %
Network Frequency47.5…63 Hz
Output voltage<= power supply voltage
[Uc] control circuit voltageBuilt into the starter
Starting timeAdjustable from 1 to 10 s
Deceleration time symbAdjustable from 1 to 10 s
Starting torque30…80 % of starting torque of motor connected directly on the line supply
Discrete input typeLogic LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
Discrete input voltage24…40 V
Discrete input logicPositive LI1, LI2, BOOST < 5 V <= 0.2 mA > 13 V, >= 0.5 mA
Discrete output current2 A DC-13
3 A AC-15
Discrete output typeOpen collector logic LO1 end of starting signal
Relay outputs R1A, R1C NO
Discrete output voltage24 V 6…30 V) open collector logic
Minimum switching current10 mA 6 V DC relay outputs
Maximum switching currentRelay outputs 2 A 250 V AC cos phi = 0.5 20 ms inductive
Relay outputs 2 A 30 V DC cos phi = 0.5 20 ms inductive
Display type1 LED Green)starter powered up
1 LED Yellow)nominal voltage reached
Tightening torque4.43 lbf.in (0.5 N.m)
16.82…22.13 lbf.in (1.9…2.5 N.m)
Electrical connection4 mm screw clamp terminal – rigid 1 1…10 mm² AWG 8 power circuit
Screw connector – rigid without cable end 1 0.5…2.5 mm² AWG 14 control circuit
4 mm screw clamp terminal – rigid 2 1…6 mm² AWG 10 power circuit
Screw connector – rigid 2 0.5…1 mm² AWG 17 control circuit
Screw connector – flexible with cable end 1 0.5…1.5 mm² AWG 16 control circuit
4 mm screw clamp terminal – flexible without cable end 1 1.5…10 mm² AWG 8 power circuit
Screw connector – flexible without cable end 1 0.5…2.5 mm² AWG 14 control circuit
4 mm screw clamp terminal – flexible with cable end 2 1…6 mm² AWG 10 power circuit
4 mm screw clamp terminal – flexible without cable end 2 1.5…6 mm² AWG 10 power circuit
Screw connector – flexible without cable end 2 0.5…1.5 mm² AWG 16 control circuit
markingCE
Operating positionVertical +/- 10 degree
Height4.88 in (124 mm)
Width1.77 in (45 mm)
Depth5.16 in (131 mm)
Net Weight0.93 lb(US) (0.42 kg)
Compatibility codeATS01N2
Motor power range AC-32.2…3 kW 200…240 V 3 phase
Motor starter typeSoft starter
Environment
Electromagnetic compatibilityConducted and radiated emissions level B CISPR 11
Conducted and radiated emissions level B IEC 60947-4-2
Damped oscillating waves level 3 IEC 61000-4-12
Electrostatic discharge level 3 IEC 61000-4-2
EMC immunity level 3 EN 50082-1
EMC immunity level B EN 50082-2
Harmonics level 3 IEC 1000-3-2
Harmonics level 3 IEC 1000-3-4
Immunity to conducted interference caused by radio-electrical fields level 3 IEC 61000-4-6
Immunity to electrical transients level 4 IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3
Micro-cuts and voltage fluctuation IEC 61000-4-11
Voltage/current impulse level 3 IEC 61000-4-5
StandardsEN/IEC 60947-4-2
Product CertificationsC-tick
GOST
UL
CCC
CSA
IP Degree of ProtectionIP20
Pollution degree2 EN/IEC 60947-4-2
Vibration resistance1 gn 13…150 Hz)EN/IEC 60068-2-6
1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6
Shock resistance15 gn 11 ms EN/IEC 60068-2-27
Relative humidity5…95 % without condensation or dripping water EN/IEC 60068-2-3
Ambient air temperature for operation14…104 °F (-10…40 °C) without derating)
104…122 °F (40…50 °C) with current derating of 2 % per °C)
Ambient air temperature for storage-13…158 °F (-25…70 °C) EN/IEC 60947-4-2
Operating altitude<= 3280.84 ft (1000 m) without derating
> 3280.84 ft (1000 m) with current derating of 2.2 % per additional 100 m
Ordering and shipping details
CategoryUS10I1122392
Discount Schedule0I11
GTIN3389110667257
ReturnabilityYes
Country of originUS
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.17 in (5.500 cm)
Package 1 Width5.98 in (15.200 cm)
Package 1 Length6.89 in (17.500 cm)
Package 1 Weight18.80 oz (533.000 g)
Unit Type of Package 2S03
Number of Units in Package 214
Package 2 Height11.81 in (30.000 cm)
Package 2 Width11.81 in (30.000 cm)
Package 2 Length15.75 in (40.000 cm)
Package 2 Weight17.64 lb(US) (8.001 kg)
Product Description

Schneider Driver

Frequently Asked Questions

A soft starter continuously controls the motor's voltage supply during the start-up phase. By adjusting the motor to the machine's load behavior, it ensures that mechanical operating equipment accelerates smoothly. This gradual acceleration lengthens the service life of the equipment, improves operating behavior, and smooths workflows, leading to more efficient and reliable operations.

A Schneider Electric drive, often referred to as a variable frequency drive (VFD) or variable speed drive (VSD), is an advanced device used to control the speed and torque of electric motors. These drives are integral components in modern industrial automation, providing precise motor control, energy efficiency, and enhanced operational performance.

✅ The primary difference between a Variable Frequency Drive (VFD) and a soft starter is their functionality. A VFD can vary the speed of a motor, providing precise control over its operation, while a soft starter only controls the starting and stopping phases of the motor. When considering an application, soft starters are typically more cost-effective and compact. However, if speed control is required, a VFD is the better choice.

✅ The primary difference between a Variable Frequency Drive (VFD) and a soft starter is their functionality. A VFD can vary the speed of a motor, providing precise control over its operation, while a soft starter only controls the starting and stopping phases of the motor. When considering an application, soft starters are typically more cost-effective and compact. However, if speed control is required, a VFD is the better choice.

Essentially, a Variable Frequency Drive (VFD) functions as a soft starter with added speed control capabilities. If your application requires speed variation, a VFD is the ideal choice. However, if you only need to control the inrush of current during startup and prefer a smaller, more cost-effective device, a soft starter is the better option.

Reviews

There are no reviews yet.

Be the first to review “ATS01N212LU”

Your email address will not be published. Required fields are marked *

Start typing to see products you are looking for.