5SY5232-7
Circuit breaker Universal current 440 V DC 400 V AC 10kA, 2-pole, C, 32A
- Stock status:
- Call for availability
- Manufacturer:
- Siemens
- Product code:
- 5SY5232-7
Main documents
- Product datasheet
- Instruction sheet
- Catalogue
Related products
| Product | |
| Article Number (Market Facing Number) | 5SY5232-7 |
| Product Description | Circuit breaker Universal current 440 V DC 400 V AC 10kA, 2-pole, C, 32A |
| Product family | Basic Devices |
| Product Lifecycle (PLM) | Active Product |
| Price data | |
| Region Specific PriceGroup / Headquarter Price Group | 12B / 1AC |
| List Price | Show prices |
| Customer Price | Show prices |
| Surcharge for Raw Materials | None |
| Metal Factor | L-O—– |
| Additional Product Information | |
| EAN | 4001869226729 |
| UPC | Not available |
| Commodity Code | 85362010 |
| LKZ_FDB/ CatalogID | LV10.1 |
| Product Group | 5505 |
| Group Code | P310 |
| Country of origin | Germany |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.10.2006 |
| Product class | B: return restricted, please contact your Siemens partner/contact |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0,1 % (w / w) |
| SCIP number | 24d71f1b-468d-4b66-bb33-d4f0151b0d4d |
Product Description
5SY5232-7
The Siemens 5SY5232-7 is a 2-pole Miniature Circuit Breaker (MCB) engineered for universal current applications. Designed to protect both AC (400 V) and DC (440 V) circuits, it ensures dependable protection against overloads and short circuits. With its C-characteristic tripping curve, the breaker is well-suited for applications with moderate inrush currents, such as lighting, small motors, and mixed load systems.

Key Features and Specifications
- Rated Current (In): 32 A
- Rated Voltage (Un): 400 V AC / 440 V DC
- Breaking Capacity: 10 kA
- Poles: 2
- Tripping Curve: C Characteristic (for circuits with moderate inrush currents)
- Mounting: DIN rail compatible
- Product Type: Universal Current Miniature Circuit Breaker

Technical Information
- Number: 5SY5232-7
- EAN: 4001869226729
- Commodity Code: 85362010
- Catalog Reference: LV10.1
- Product Group: 5505
- Group Code: P310
- Lifecycle Status: Active Product
- Country of Origin: Germany
- Product Class: B (return restricted – contact Siemens partner)
Applications
- Protection of control and distribution circuits in residential, commercial, and industrial installations
- Suitable for both AC and DC systems requiring reliable overcurrent protection
- Ideal for circuits with moderate inrush currents and mixed load profiles
- Enhances operational safety and system reliability by effectively limiting fault currents
Summary:
The Siemens 5SY5232-7 Miniature Circuit Breaker offers reliable performance and universal flexibility. With a rated current of 32 A, dual AC/DC compatibility, and a 10 kA breaking capacity, it provides robust protection for modern low-voltage distribution networks. Its C-curve tripping characteristic ensures dependable operation in applications with moderate inrush currents, making it a versatile and durable choice for electrical protection systems.
Frequently Asked Questions
What is MCB protection?
✅ MCB (Miniature Circuit Breaker) protects against overloads and short circuits. Overload protection works via a bimetallic strip (thermal operation), while short-circuit protection uses a tripping coil (electromagnetic operation). This ensures electrical safety in homes, businesses, and industries.
What is the rule for installing an SPD?
✅ SPD (Surge Protection Device) connections should be as short as possible to minimize the voltage protection level (Up). The total length of connections to the network and earth should not exceed 50 cm to ensure effective surge protection.
How to Set Up a Surge Protector?
1.Turn off power at the circuit breaker.
2. Remove the old outlet.
3. Connect wires to the new surge-protected outlet per the manufacturer’s instructions.
4. Secure the outlet in the box and replace the cover plate.
5. Restore power and test the outlet.
What is the use of RCCB in Siemens?
✅ Siemens Residual Current Circuit Breakers (RCCBs) protect against electric shock by detecting leakage currents. If the leakage exceeds a set limit, the RCCB immediately disconnects the circuit, ensuring safety from direct or indirect contact with live components.
Where is an RCBO used?
✅ RCBOs (Residual Current Circuit Breakers with Overcurrent protection) are commonly used in various residential, commercial, and industrial applications. Typical use cases include power distribution boards, emergency lighting circuits, HVAC (Heating, Ventilation, and Air Conditioning) systems, socket outlets, and swimming pool equipment. RCBOs are ideal for protecting individual circuits where both earth fault and overcurrent protection are required.
Where to Install RCCB?
✅ RCCBs should be installed in the distribution board (DB box) or circuit breaker panel to protect against current leakages caused by faulty wiring, ageing insulation, or defective appliances.