RangeComPact
Product nameComPacT INS
product or component typeSwitch disconnector
Poles description3P
Network typeAC
DC
Network frequency50/60 Hz
[Ie] rated operational currentAC-22A: 125 A AC 50/60 Hz 220/240 V
AC-22A: 125 A AC 50/60 Hz 380/415 V
AC-22A: 125 A AC 50/60 Hz 440/480 V 2 poles in series
AC-22A: 125 A AC 50/60 Hz 500 V 2 poles in series
AC-22A: 125 A AC 50/60 Hz 660/690 V
AC-23A: 125 A AC 50/60 Hz 220/240 V
AC-23A: 125 A AC 50/60 Hz 380/415 V
AC-23A: 125 A AC 50/60 Hz 440/480 V
AC-23A: 125 A AC 50/60 Hz 500 V
AC-23A: 80 A AC 50/60 Hz 660/690 V
DC-22A: 125 A DC 50/60 Hz 125 V 2 poles in series
DC-23A: 125 A DC 50/60 Hz 125 V 2 poles in series
[Ui] rated insulation voltage750 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current125 A at 60 °C
[Icm] rated short-circuit making capacity154 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz
20 kA switch-disconnector alone 690 V AC at 50/60 Hz
[Ue] rated operational voltage125 V DC
690 V AC 50/60 Hz
Suitability for isolationYes
Contact position indicatorYes
Visible breakNo
Pollution degree3
Complementary
Control typeRotary handle
handle colourBlack
Mounting modeFixed
Mounting supportDIN rail
Plate
Upside connectionFront
downside connectionFront
Maximum powerAC-23: 55 kW at 440 V AC 50/60 Hz
AC-23: 37 kW at 220/240 V AC 50/60 Hz
AC-23: 55 kW at 380/415 V AC 50/60 Hz
AC-23: 75 kW at 500/525 V AC 50/60 Hz
AC-23: 75 kW at 660/690 V AC 50/60 Hz
Rated dutyUninterrupted
Intermittent duty classClass 120 – 60 %
enclosure dimensions for Ithe260 mm x 160 mm x 55 mm
[Icw] rated short-time withstand current0.01 kA during 30 s conforming to IEC 60947-3
1.23 kA during 20 s conforming to IEC 60947-3
3.175 kA during 3 s conforming to IEC 60947-3
5.5 kA during 1 s conforming to IEC 60947-3
Mechanical durability15000 cycles
Electrical durabilityAC-22A: 1500 cycles 220/240 V AC 50/60 Hz
AC-22A: 1500 cycles 380/415 V AC 50/60 Hz 2 poles in series
AC-22A: 1500 cycles 440 V AC 50/60 Hz
AC-22A: 1500 cycles 500 V AC 50/60 Hz
AC-23A: 1500 cycles 220/240 V AC 50/60 Hz
AC-23A: 1500 cycles 380/415 V AC 50/60 Hz
AC-23A: 1500 cycles 440 V AC 50/60 Hz
AC-23A: 1500 cycles 500 V AC 50/60 Hz
DC-22A: 1500 cycles 250 V DC 50/60 Hz 2 poles in series
DC-23A: 1500 cycles 250 V DC 50/60 Hz 2 poles in series
AC-22A: 1500 cycles 690 V AC 50/60 Hz
AC-23A: 1500 cycles 690 V AC 50/60 Hz 2 poles in series
Connection pitch30 mm
Height100 mm
Width135 mm
Depth62.5 mm
net weight0.8 kg
Environment
StandardsIEC 60947-1
IEC 60947-3
Product certificationsCCC
KEMA-KEUR
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-50…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height13.400 cm
Package 1 Width11.400 cm
Package 1 Length15.500 cm
Package 1 Weight1.022 kg
Unit Type of Package 2S03
Number of Units in Package 210
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.680 kg
Unit Type of Package 3P12
Number of Units in Package 380
Package 3 Height43.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight97.000 kg
Product Description

Schneider Switch Disconnector

Frequently Asked Questions

A switch serves as a vital control device, capable of supplying and interrupting the current flow required by consumers or control circuits throughout an appliance's lifespan. Meanwhile, a disconnector acts as a crucial safety feature, isolating the power supply to render the device inert for interlocking or maintenance purposes.

A disconnector requires manual operation to cut power, ensuring circuit safety during maintenance but lacking overload protection. In contrast, a circuit breaker serves as a protective device, capable of thermally or magnetically tripping to safeguard circuits from overloads.

The switch disconnector is a widely used distribution equipment in factories, offering manual circuit switching, breaking, and power isolation capabilities. Additionally, the fuse switch disconnector provides effective short-circuit and overload protection for cables and power equipment within distribution systems.

Apart from adhering to IEC standards, compliance with the National Electric Code (NEC) requires the inclusion of a disconnect switch. According to this code, all large and permanently wired equipment must feature a disconnecting means within visible range.

In simple terms, a switch toggles power on and off, while a circuit breaker interrupts the circuit during overload or faults. Switches control power, whereas breakers manage circuit interruptions. Recognizing these distinctions is vital for grasping their safety and utility.

Reviews

There are no reviews yet.

Be the first to review “28910”

Your email address will not be published. Required fields are marked *

Start typing to see products you are looking for.